– 17 –
TO PROGRAM
SYSTEM STATUS
AND RESTORE
REPORT CODES
(
✱
60 –
✱
68,
✱
70 –
✱
75)
With Ademco Contact ID Reporting: Enter any digit (other than "0") in
the first box, to enable zone to report This is an "enabling" code only and is
disregarded in the actual reporting to the central office. Entries in the second
boxes will be ignored.
A "0" (not "# + 10") in the first box will disable the report.
Examples:
For Code 3 (Single Digit), enter:
3 0
For Code 32 (Two Digits), enter:
3 2
For Code B2 (Hexadecimal) enter:
# +
11
2
SYSTEM STATUS
REPORT CODES
(
✱
60 –
✱
68)
✱
60
TROUBLE REPORT CODE (See box above.)
(2-Digit Entry)
✱
61
BYPASS REPORT CODE (See box above.)
(2-Digit Entry)
✱
62
AC LOSS REPORT CODE (See box above.)
(2-Digit Entry)
Reports with Subscriber No. Timing of this report is random with up to
a 48-minute delay. The Restore report has a random delay of up to about
12 minutes. If AC restores before the report goes out, there is no AC
restore report.
✱
63
LOW BAT REPORT CODE (See box above.)
(2-Digit Entry)
Reports with Subscriber No.
✱
64
TEST REPORT CODE (See box above.)
(2-Digit Entry)
Periodic Reports with Subscriber No.
✱
65
OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
(2-Digit Entry)
Open Report Code: To enable, enter a code (or 0 to disable) in the left-
hand box (see box above).
Exit Alarm Report Code: To enable, enter a code (or 0 to disable) in
the right-hand box (see box above). If enabled, any alarm from an exit
or interior zone occurring within two minutes after the end of
the exit delay will send a special message indicating exit alarm to the
central station, and a zone indication and "Exit Alarm" or "EA" is
displayed on the touchpad.
If an exit or interior zone contains a fault as the exit delay ends,
the local bell and touchpad sound continuously.
a)
If the subscriber then disarms the system before the ensuing Entry
delay ends , no message is transmitted to the central station, but a
zone indication and "Canceled Alarm" or "CA" is displayed on the
touchpad.
b)
If the system is not disarmed before that entry delay ends, a special
message indicating Exit Alarm is sent to the central station and a
zone indication and "Exit Alarm" or "EA" is displayed on the
touchpad.
For Contact ID reporting, Event code 374 and the zone number is sent.
✱
66
AWAY/STAY CLOSE REPORT CODE
(2-Digit Entry)
(See box above.)
To enable, enter a code (or 0 to disable) in either or both boxes.
✱
67
RF XMTR. LOW BATTERY REPORT CODE
(2-Digit Entry)
(See box above).
✱
68
CANCEL REPORT CODE
(2-Digit Entry)
(See box above).
RESTORE
REPORT CODES
(
✱
70 –
✱
75)
✱
70
ALARM RESTORE REPORT CODE
(See box above).
✱
71
TROUBLE RESTORE REPORT CODE
(2-Digit Entry)
(See box above). This is sent when a trouble in a zone is restored.
Содержание SA10ADTEG
Страница 22: ... 22 NOTES ...