– 10 –

ALPHA VOCABULARY LIST

(For Entering Zone Descriptors)

NOTE

: Some rarely used words appearing in previously published lists have been deleted from this list. Use only

this list for selecting zone descriptors.

000

(Word Space)
– A –

• 001

AIR

• 002

ALARM

004

ALLEY

005

AMBUSH

• 006

AREA

• 007

APARTMENT

• 009

ATTIC

010

AUDIO
– B –

• 012

BABY

• 013

BACK

• 014

BAR

• 016

BASEMENT

• 017

BATHROOM

• 018

BED

• 019

BEDROOM

020

BELL

• 021

BLOWER

• 022

BOILER

023

BOTTOM

025

BREAK

• 026

BUILDING
– C –

028

CABINET

• 029

CALL

030

CAMERA

031

CAR

033

CASH

034

CCTV

035

CEILING

036

CELLAR

• 037

CENTRAL

038

CIRCUIT

• 040

CLOSED

• 046

COMPUTER

047

CONTACT

 

– D –

• 048

DAUGHTERS

049

DELAYED

• 050

DEN

051

DESK

• 052

DETECTOR

• 053

DINING

054

DISCRIMINATOR

055

DISPLAY

• 057

DOOR

• 059

DOWN

• 060

DOWNSTAIRS

061

DRAWER

• 062

DRIVEWAY

• 064

DUCT
– E –

• 065

EAST

066

ELECTRIC

067

EMERGENCY

068

ENTRY

• 069

EQUIPMENT

• 071

EXIT

072

EXTERIOR
– F –

• 073

FACTORY

075

FAMILY

• 076

FATHERS

• 077

FENCE

• 079

FIRE

• 080

FLOOR

081

FLOW

082

FOIL

• 083

FOYER

084

FREEZER

• 085

FRONT
– G –

• 089

GARAGE

• 090

GAS

091

GATE

• 092

GLASS

093

GUEST

094

GUN
–  H –

• 095

HALL

• 096

HEAT

098

HOLDUP

099

HOUSE

100

INFRARED

• 101

INSIDE

102

INTERIOR

103

INTRUSION
– J –

104

JEWELRY
– K –

• 105

KITCHEN

– L –

• 106

LAUNDRY

• 107

LEFT

108

LEVEL

• 109

LIBRARY

• 110

LIGHT

111

LINE

• 113

LIVING

• 114

LOADING

115

LOCK

116

LOOP

117

LOW

• 118

LOWER
– M –

• 119

MACHINE

121

MAIDS

122

MAIN

• 123

MASTER

• 125

MEDICAL

126

MEDICINE

128

MONEY

129

MONITOR

• 130

MOTHERS

• 131

MOTION

132

MOTOR
– N –

• 134

NORTH

135

NURSERY
– O –

• 136

OFFICE

• 138

OPEN

139

OPENING

• 140

OUTSIDE

142

OVERHEAD
– P –

143

PAINTING

• 144

PANIC

145

PASSIVE

• 146

PATIO

147

PERIMETER

• 148

PHONE

150

POINT

151

POLICE

152

POOL

• 153

POWER

– R –

155

RADIO

• 156

REAR

157

RECREATION

159

REFRIGERATION

160

RF

• 161

RIGHT

• 162

ROOM

163

ROOF
– S –

164

SAFE

165

SCREEN

166

SENSOR

• 167

SERVICE

• 168

SHED

169

SHOCK

• 170

SHOP

171

SHORT

• 173

SIDE

174

SKYLIGHT

175

SLIDING

• 176

SMOKE

• 178

SONS

• 179

SOUTH

180

SPRINKLER

• 182

STATION

184

STORE

• 185

STORAGE

186

STORY

190

SUPERVISED

191

SUPERVISION

192

SWIMMING

193

SWITCH
– T –

194

TAMPER

196

TELCO

197

TELEPHONE

• 199

TEMPERATURE

200

THERMOSTAT

• 201

TOOL

202

TRANSMITTER
– U –

• 205

UP

• 206

UPPER

• 207

UPSTAIRS

• 208

UTILITY

– V –

209

VALVE

210

VAULT

212

VOLTAGE
– W –

213

WALL

214

WAREHOUSE

• 216

WEST

• 217

WINDOW

• 219

WING

220

WIRELESS
– X –

222

XMITTER
– Y –

223

YARD
– Z –

224

ZONE (No.)

• 225

ZONE

• 226

0

• 227

1

• 228

1ST

• 229

2

• 230

2ND

• 231

3

• 232

3RD

• 233

4

• 234

4TH

• 235

5

• 236

5TH

• 237

6

• 238

6TH

• 239

7

• 240

7TH

• 241

8

• 242

8TH

• 243

9

• 244

9TH

245

Custom Word #1

246

Custom Word #2

247

Custom Word #3

248

Custom Word #4

249

Custom Word #5

250

Custom Word #6

251

Custom Word #7

252

Custom Word #8

253

Custom Word #9

254

Custom Word #10

Note:

Bulleted () words in  boldface type are those that are also available for use by the 4285 Phone Module. If using a
Phone module, and words other than these are selected for Alpha descriptors, the module will not provide annunciation
of those words.

CHARACTER (ASCII) CHART

(For Adding Custom Words)

32 (space)
33 !
34 "
35 #
36 $
37 %
38 &
39 '
40 (
41 )

42 *
43 +
44 ,
45 –
46 .
47 /
48 0
49 1
50 2
51 3

52 4
53 5
54 6
55 7
56 8
57 9
58 :
59 ;
60 <
61 =

62 >
63 ?
64 @
65 A
66 B
67 C
68 D
69 E
70 F
71 G

72 H
73 I
74 J
75 K
76 L
77 M
78 N
79 O
80 P
81 Q

82 R
83 S
84 T
85 U
86 V
87 W
88 X
89 Y
90 Z

Содержание SA10ADTEG

Страница 1: ... Systems Programming GuideÊ For Standard Controls ARMED READY PANIC OFF AWAY STAY MAX TEST BYPASS INSTANT CODE CHIME READY 1 2 3 6 5 4 8 9 7 0 ALARM CHECK FIRE AWAY STAY INSTANT BYPASS NO AC CHIME BAT NOT READY N7227 2PRGDV2 1 00 Model SA10ADTEG ...

Страница 2: ...83 8 Exiting the Programming Mode 8 5800 Series Transmitter Input Loop Identification 9 Alpha Vocabulary List For Entering Zone Descriptors 10 Character ASCII Chart For Adding Custom Words 10 Zone Response Type Definitions 11 Data Field Descriptions in numerical order 13 Remote Programming and Control Downloading 20 General Information 20 Equipment Required 20 Remote Programming Information 20 Rem...

Страница 3: ...e 1 4 min 2 8 min 3 12 min 4 16 min 36 EXIT DELAY 6 0 00 99 seconds 37 ENTRY DELAY 1 4 5 00 99 seconds 38 ENTRY DELAY 2 1 0 00 99 seconds 39 AUDIBLE EXIT WARNING 1 0 no 1 yes DIALER PROGRAMMING 40 50 In fields 40 41 42 enter up to the number of digits shown Do not fill unused spaces Enter 0 9 11 for 12 for 13 for a pause 40 PABX ACCESS CODE Enter up to 6 digts If fewer than 6 digits entered exit b...

Страница 4: ...minal 53 ZONE TYPE 25 RESPONSE TIME 0 0 15 seconds For 1 15 minutes enter 1 9 10 for 10 min 11 for 11 min 12 for 12 min 13 for 13 min 14 for 14 min 15 for 15 min Entry of a number other than one specified will give unpredictable results 56 ZONE ASSIGNMENT ALARM REPORT CODES See explanation on next page ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT DESCRIPTION No TYPE Hex DEVICE LOOP Zn ZT RC In L Z...

Страница 5: ...ALARM RESTORE RPRT CODE 1 71 TROUBLE RESTORE RPRT CODE 1 0 72 BYPASS RESTORE RPRT CODE 0 0 73 AC RESTORE REPORT CODE 0 0 74 LOW BAT RESTORE RPRT CODE 1 0 75 RF XMTR LO BAT RST CODE 1 0 OUTPUT AND SYSTEM SETUP 80 92 80 OUTPUT RELAYS Program 80 and 81 only if 81 ZONE LISTS FOR Relays are to be used OUTPUT RELAYS See next page 82 CUSTOM ALPHA EDITING Also entered from field 56 See procedure in instru...

Страница 6: ...ot be same list as used for START ZT ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 06 24 Hr Silent 01 Entry Exit 1 07 24 Hr Audible 02 Entry Exit 2 08 24 Hr Aux 03 Perimeter 09 Fire Trouble 04 Interior Follower 10 Interior w Delay 05 Trouble Day Alarm Night Note Any zone in ZT going into alarm fault or trouble will actuate relay Any zone of that type that restores will stop rel...

Страница 7: ... programming and interactive menu mode programming Data field programming is used for setting various system options and menu programming is used for programming zone information programming relay outputs and for enrolling 5800 series transmitter serial numbers To program the system you must use a 6139ADT two line Custom English touchpad connected to touchpad terminals on the control 4 5 6 7 A Cus...

Страница 8: ... Menu Mode Used To Program 56 Zone Programming Zone characteristics report codes alpha descriptors and serial numbers for 5800 transmitters 80 Relay Programming 4204 Relay modules 81 Zone List Programming Zone Lists for 4204 relay activation 82 Alpha Programming Zone alpha descriptors 83 Sequential Mode 5800 series transmitter serial numbers Serial numbers for 5800 transmitters can also be program...

Страница 9: ...Button RF Type only send fault signals Restore or check in signals are not sent but low battery signals are sent when a button is pressed The transmitter may be carried off premises 3 4 1 2 ALWAYS USE INPUT LOOP 5801 LEARN AS UR OR RF INPUT LOOP 1 5802MN LEARN AS UR OR RF YOU MUST LEARN THIS BUTTON LOOP 3 LOOP 1 LOOP 2 LOOP 4 INPUT LOOP 1 5808 LEARN AS RF 5804 LEARN AS BR 5817 LEARN AS RF INPUT LO...

Страница 10: ...ING 140 OUTSIDE 142 OVERHEAD P 143 PAINTING 144 PANIC 145 PASSIVE 146 PATIO 147 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKYLIGHT 175 SLIDING 176 SMOKE 178 SONS 179 SOUTH 180 SPRINKLER 182 STATION...

Страница 11: ...l protect an area in the event an intruder hides on the premises prior to the system being armed or gains access to the premises through an unprotected area This zone type is bypassed automatically when the panel is armed STAY or INSTANT Type 05 Trouble by Day Alarm by Night This zone type will give an instant alarm if faulted when armed in the AWAY STAY INSTANT night modes During the disarmed sta...

Страница 12: ...r disarming Type 22 Disarm This is a special purpose zone type used with 5800 series wireless pushbutton which will result in disarming the system when the zone is activated Type 23 No Alarm Response Used with 5800 wireless system only This zone type can be used on a zone when an output relay action is desired but with no accompanying alarm e g lobby door access Type 25 This is a special purpose z...

Страница 13: ...hpads In addition a report will be sent to the central station if trouble reporting is enabled Contact ID report for RF Jam is event code 344 23 FORCED BYPASS FUNCTION 1 Digit Entry This feature allows all faulted zones to be bypassed automatically All zones that are bypassed by this function will be displayed after the bypass is initiated 0 No forced bypass 1 Allows automatic bypass of all open z...

Страница 14: ...L installations entry delay can be no greater than 45 seconds 38 ENTRY DELAY 2 2 Digit Entry The system will wait the time allotted before sounding alarm upon entering through a designated secondary entry exit location The system must be disarmed before an entry delay period ends or an alarm will occur Delay time is selectable from 00 no delay to 99 seconds 39 AUDIBLE EXIT WARNING 1 Digit Entry If...

Страница 15: ...chpad users if RF button used will send button zone number 10 17 Entries 6 through 9 will send a report to a pager using the following format AAAAAAAAAAAAAAAA BBB CCCC where A Optional Up to 16 digits for Account numbers PIN numbers or any additional data that will precede the 7 digit system status code BBB and CCCC see B and C below This optional data is programmed in field 90 PAGING CHARACTERS B...

Страница 16: ...1 to enable 1 2 second external alarm sounding ding when closing report goes in or at the end of exit delay Enter 2 for alarm sounding ding with RF arming only this will work with either a button RF unit or a 5827 0 disables the ding 52 ZONE 3 RESPONSE TIME TO OPEN 1 Digit Entry 0 400ms nominal 1 10ms nominal 53 ZONE TYPE 25 RESPONSE TIME 1 Digit Entry This zone type enables you to select a zone r...

Страница 17: ...x see box above Exit Alarm Report Code To enable enter a code or 0 to disable in the right hand box see box above If enabled any alarm from an exit or interior zone occurring within two minutes after the end of the exit delay will send a special message indicating exit alarm to the central station and a zone indication and Exit Alarm or EA is displayed on the touchpad If an exit or interior zone c...

Страница 18: ...A DESCRIPTION PROGRAMMING section in the Installation Instructions for procedure 83 SEQUENTIAL MODE Used for enrolling transmitters in a 5800 RF system after all other zone information has been programmed 90 PAGER CHARACTERS Up to 16 digits Optional 16 digits for Account numbers PIN numbers or any additional data that you wish to precede the 7 digit status code sent to a pager See field 47 SPLIT D...

Страница 19: ...Enter 1 14 No Yes Yes Enter 15 See Important Note below Important Note If 15 is entered in field 95 to bypass an answering machine and a 4285 Phone Module is included in the installation you should note the following When calling in from an off premises phone to receive a status report or execute a command the user should make the initial call allow 1 to 3 rings only and hang up Then call in again...

Страница 20: ... calls back the PC via the preprogrammed telephone number The unit can then be uploaded downloaded or controlled from your office The control can also be set for no callback by the downloader 4 Data Encryption Data passed between the PC and the control is encrypted for security so that it is very difficult for a foreign device tapped into the phone line to take over communication and substitute sy...

Страница 21: ...sent to the central station The touchpads will become active after the download communication is terminated The detailed operation of the download functions is covered in the installation instructions for the Windows Downloading Software Remote Programming Advisory Notes Alarm and trouble reporting may be delayed during the time that the system and the Downloader are linked to each other following...

Страница 22: ... 22 NOTES ...

Страница 23: ... VOLTAGE 13 8VDC BATTERY 12V 4AH e g ADEMCO No 467 OR 12V 1 2AH BATTERY CONNECTOR TABS PLUG IN TRANSFORMER 16 5VAC 25VA e g ADEMCO No 1321 TO 110VAC UNSWITCHED OUTLET 24 HR ALARM OUTPUT 10 5 13 8VDC 2A MAX 600mA MAX FOR UL USAGE INCLUDING AUX POWER STEADY FOR BURGLARY PANIC TEMPORAL SOUNDING FOR FIRE e g USE ADEMCO No 740 SOUNDER Nos 702 OR 719 SIREN OR 12V BELL BATTERY FUSE e g ADEMCO No 90 12 FO...

Страница 24: ...ADT Security Services Inc 1750 Clint Moore Rd Boca Raton FL 33431 Copyright 2000 àN7227 2PRGDV2Uä N7227 2PRGDV2 1 00 ...