– 4 –
✱
47
SPLIT/DUAL REPORTING
0
0 = Disable (Backup report only)
TO PRIMARY PHONE No.
TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel
Other Reports
2 = All Reports except Open/Close, Test
Open/Close, Test
3 = Alarms, Restore, Cancel
All Reports
4 = All Reports except Open/Close, Test
All Reports
5 = All Reports
(
Dual Reporting)
All Reports
TO PRIMARY PHONE No.
TO PAGING No.
(SECONDARY)
6 = All reports except Open/Close
*
Alarms, Open/Close (for users 4–17
†
), Troubles
7 = All reports
*
Alarms, Troubles
8 = All reports
*
Alarms, Open/Close (for users 4–17
†
), Troubles
9 = All reports except Open/Close
*
Open/Close for Users 4–17
†
† 4–8 for touchpad users; if RF button used, will send button zone number 10–17.
*
A code is sent to the pager. See DATA FIELD DESCRIPTIONS for an explanation of the code.
✱
48
15 SEC DIALER DELAY (BURG)
†
1
0 = no; 1 = yes
✱
49
PERIODIC TEST MESSAGE
†
3
0 = none; 1 = 24 hrs; 2 = wkly; 3 = monthly. Test Code required in field
✱
64.
✱
51
CONFIRMATION OF ARMING DING
†
0
0 = no; 1 = yes ; 2 = yes, but with RF arming only.
✱
52
ZONE 3 RESPONSE TO OPEN
†
0
0 = 400 ms nominal; 1 = 10 ms nominal
✱
53
ZONE TYPE 25 RESPONSE TIME
0
0 = 15 seconds. For 1–15 minutes, enter 1–9, #+10 for 10 min, #+11 for 11
min,
#+12 for 12 min, #+13 for 13 min, #+14 for 14 min, #+15 for 15 min.
†
Entry of a number other than one specified will give unpredictable results.
✱
56
ZONE ASSIGNMENT/ALARM REPORT CODES
(See explanation on next page)
ZONE
ZONE
ZONE
ALARM RPT CODE
INPUT
RF INPUT
DESCRIPTION
No.
TYPE
(Hex)
DEVICE
LOOP
(Zn)
(ZT)
(RC)
(In)
(L)
ZONES ON CONTROL:
Wired Zone 1
0
1
0
1
0
1
0
0
HW
—
Wired Zone 2
0
2
0
1
0
1
0
0
HW
—
Wired Zone 3
0
3
1
0
0
1
0
0
HW
—
Wired Zone 4
0
4
1
0
0
1
0
0
HW
—
Wired Zone 5
0
5
0
9
0
1
0
0
HW
—
Wired Zone 6
0
6
0
1
0
1
0
0
HW
—
—
—
Duress
0
8
—
—
0 0
0
0
—
—
Tamper
0
9
0
5
0
1
0
0
—
—
Touchpad Panic (1 &
✱
,
or A)
9
5
0
9
0
1
0
0
—
—
Touchpad Panic (3 & #, or C)
9
6
0
0
0
0
0
0
—
—
Touchpad Panic (
✱
& #, or B)
9
9
0
7
0
1
0
0
RF EXPANSION ZONES:
With 5881L, up to 8; 5881M or 5881H, up to 16.
ENTER FOR
[
5800 0NLY
[
1st RF Expansion Zone
1
0
0
1
0
1
0
0
2nd
1
1
0
1
0
1
0
0
3rd
1
2
0
1
0
1
0
0
4th
1
3
1
0
0
1
0
0
5th
1
4
1
0
0
1
0
0
6th
1
5
1
0
0
1
0
0
7th
1
6
1
0
0
1
0
0
8th
1
7
1
0
0
1
0
0
9th
1
8
0
1
0
1
0
0
10th
1
9
0
1
0
1
0
0
11th
2
0
0
9
0
1
0
0
12th
2
1
0
9
0
1
0
0
13th
2
2
2
3
0
0
0
0
5
1
14th
2
3
2
2
0
0
0
0
5
2
15th
2
4
2
0
0
0
0
0
5
4
16th
2
5
2
1
0
0
0
0
5
3
Содержание SA10ADTEG