30
Signal Connections
Leading
EDGE COMPUTING
3.3.2.2
Direction End Limit Signal (PEL / MEL)
The end-limit switches are usually installed on both ends of an
axis. The positive EL must be installed at the positive position of
the axis, and vice versa. If they are installed reversely, the protec-
tion will be invalid. These two signals are for safety, which can pre-
vent a machine crash when missing an operation.
The AMP-104C provides two direction end limit signals, PEL and
MEL, for each axis. PEL indicates the end limit signal is in the pos-
itive direction and MEL indicates the end limit signal is in the nega-
tive direction.
The external limit switch should have a contact capacity of +24V at
10mA minimum. The EL logical can be configured via switch.
Axis #
CN2 Pin No.
Signal Name
CN2 Pin No.
Signal Name
0
10
PEL0
11
MEL0
1
15
PEL1
16
MEL1
2
20
PEL2
21
MEL2
3
25
PEL3
26
MEL3
EL
AMP-104C
CN2
E L
E 2 4 V
D 3 V 3
DGND
E G N D
DGND
T o F P G A
P S 2 8 0 5
1
2
4
3
R
4 .7 K _ + -5 %
R
R
Vcc
Gnd
S N 7 4 L V C 1 4 A
3
7
4
14
C
Содержание AMP-104C
Страница 6: ...vi Table of Contents Leading EDGE COMPUTING This page intentionally left blank...
Страница 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...
Страница 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...
Страница 16: ...6 Introduction Leading EDGE COMPUTING This page intentionally left blank...
Страница 30: ...20 Getting Started Leading EDGE COMPUTING This page intentionally left blank...
Страница 46: ...36 Signal Connections Leading EDGE COMPUTING This page intentionally left blank...
Страница 52: ...42 Consignes de S curit Importante Leading EDGE COMPUTING This page intentionally left blank...