![Adey FL1-03-06631 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/adey/fl1-03-06631/fl1-03-06631_installation-and-servicing_3047375014.webp)
14
*NOTE: PARAMETER 1:
- If Parameter 1 “Cartridge Present” is set to “YES”, Parameters 2 & 3 are not activated.
- If Parameter 1 “Cartridge Present” is set to “NO”, Parameters 2 & 3 are activated and the timer
will be active from that point.
**NOTE: PARAMETER 2:
- Parameter 2 “Magnet Only Service Warning” setting, (Daily, Weekly or Monthly) will affect the
default value of Parameter 3 “Magnet Only Service Warning Duration”, e.g. with Parameter 2 set
at the default “Daily” setting, the controller will provide a warning alarm every 2 days by default.
If Parameter 2 is changed to “Weekly” the controller will provide a warning alarm every 2 weeks.
Default Parameter 3 values can be manually changed during Parameter Programming Mode
within a range of 1 – 12 days, weeks or months as applicable.
PARAMETER PROGRAMMING MODE - CUSTOMER DATA MENU
(Code: 815)
PRESS & HOLD ‘SET’ & ‘UP’ TO PASS TO PARAMETER MENUS
#
Parameter
Description
Default
Range
P1
Cartridge Present
Monitors presence of a filter cartridge
No
Yes/No
P4
ID Number
Address for ModBus
0
0 - 99
P5
Battery Activation
Enable or disable the battery, (maintains date &
time settings if power lost to the controller - on
first power up, battery will automatically activate
No
Yes/No
DL1
Last Service Date
Automatically updates when a new service date
has been entered and will be visible next time the
user accesses parameters
-
-
DL2
Service Date
Automatically updates when a new service date
has been entered
Auto-
Update
DL3
Pump Hours
Total pump operation time (Auto-Update)
Auto-
Update
DL4
Current water
flow I/min
Flow rate through sensor at that point in time
Auto-
Update
DL5
Water Volume in
last 24 hours
Amount of water that has passed through the filter
during the previous 24 hours
Auto-
Update
DL6
Water volume
since last
Pressure
Difference Alarm
activation
Flow rate through sensor at that point in time
Auto-
Update
DL7
Total Water
Volume
Total amount of water that has passed through the
filter since the unit was last powered ON
Auto-