![Adeunis RF COMFORT MQTT Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/adeunis-rf/comfort-mqtt/comfort-mqtt_user-manual_3047350020.webp)
User Guide | COMFORT SERENITY MQTT | NB-IoT / LTE-Cat-M1
20
RF specifications
NB-IoT
LTE-Cat-M1
Power Consumption
Reduction Feature
PSM
PSM
2.4 Updates
Application configuration
Configuration via NFC using the Adeunis
NFC IoT Configurator mobile application on
Android or remotely
Firmware update
Not supported
2.5 Integrated sensor specifications
Specifications
Value
Temperature
Technology
CMOSens
Recommended Operating
Range
-0°C / +65°C
Accuracy
± 0.2°C typ. ± 1°C max.
Typical Resolution
0.01°C
Humidity
Technology
CMOSens
Recommended Operating
Range
10% / 90% HR
Accuracy
± 2% HR typ. ± 4.5% HR
max.
Typical Resolution
0.01 % HR
CO2
Technology
NDIR (Non-Dispersive
Infrared)
Operating Conditions
0°C / +50°C 0% / 85% HR
Measurement Range
Up to 5,000 ppm; extended
range up to 10,000 ppm
Accuracy
± 30 ppm +3% of the reading
within the range up to 5,000
ppm
Resolution
1 ppm
VOC (optional)
Technology
MOX
Operating Conditions
-10°C / +50°C 0% / 90% HR
Содержание COMFORT MQTT