– 69 –
Press
✱
63
LOW BAT REPORT CODE
This will be sent when a low battery condition exists in the
system’s standby battery.
Note: Connection to the standby battery is checked every 3
minutes (CSFM requirement).
Press
✱
64
TEST REPORT CODE
This is sent periodically to test that the communicator and phone
lines are operational (frequency of report is selected in field
✱
51).
Press
✱
65
OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code : To enable, enter a code (or 0 to disable) in
the left-hand box (see box on previous page).
For expanded or 4+2 reporting, 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to
disable) in the right-hand box (see box above). If enabled, any
alarm from an exit or interior zone occurring within two
minutes after the end of the exit delay will send a special
message indicating exit alarm to the central station, and a zone
indication and "Exit Alarm" or "EA" is displayed on the keypad.
If an exit or interior zone contains a fault as the exit delay
ends, the local bell and keypad sound continuously.
a)
If the subscriber then disarms the system before the ensuing
ENTRY delay ends , no message is transmitted to the central
station, but a zone indication and "Canceled Alarm" or "CA" is
displayed on the keypad.
b)
If the system is not disarmed before that entry delay ends, a
special message indicating Exit Alarm is sent to the central
station and a zone indication and "Exit Alarm" or "EA" is
displayed on the keypad.
For expanded or 4+2 reporting, a 2nd digit is sent, and is the
same as the 2nd digit of the zone alarm report code programmed
in field
✱
56.
For Contact ID reporting, Event code 374 and the zone number is
sent.
There is no restore message for Exit Alarm report.
Press
✱
66 ARM AWAY/STAY REPORT CODES
This option allows for independent programming of AWAY and
STAY reports . 2nd digit of Report is User No., if expanded or 4+2
reporting is selected.
Press
✱
67 RF XMTR. LOW BATTERY REPORT CODE
This is sent in the event that a wireless transmitter low battery
condition exists.
Press
✱
68 CANCEL REPORT CODE
This is sent upon disarming of the system after an alarm condition
was reported.
Press
✱
70 ALARM RESTORE REPORT CODE, 1st DIGIT
This is sent when the zone that caused an alarm is restored to its
non-faulted condition. 2nd digit is automatically sent as the 2nd
digit of the zone alarm report code programmed in field
✱
56, if
expanded or 4+2 reporting is selected.
Press
✱
71 TROUBLE RESTORE REPORT CODE
This is sent when a trouble in a zone is restored.
Press
✱
72 BYPASS RESTORE REPORT CODE
This is sent when a zone that has been bypassed is un-bypassed.
Press
✱
73 AC RESTORE REPORT CODE
This is sent when AC power has been restored after an AC power
outage.