Hot plugging and mouse restoration

It is strongly recommended that you switch off the computer system before 
attempting to connect it via the X100 modules. However, if this is not possible 
then you need to ‘hot plug’ the X100 modules while power is still applied to 
the system. There is not normally a danger of damage to the system, however, 
when mouse communications are interrupted, often they fail to reinitialise 
when reconnected. X100 modules provide a feature to reinstate mouse 
communications once the necessary connections have been made.
There are two main types of data formats used by current PC mice, these are 
the older ‘PS/2’ format and the more recent ‘IntelliMouse

®

’ format introduced 

by Microsoft. These use slightly different data arrangements and it is important 
to know which type was being used before you hot-plugged the X100 modules. 
The previous setting depends both on the type of mouse and the type of 
driver as various combinations of PS/2 and Intellimouse are possible. Using the 
incorrect restore function may produce unpredictable results and require the 
system to be rebooted.

Which restore setting do I use?

The general rule is that unless both the mouse 

and

 the driver are 

both

 

Intellimouse compatible then you need to restore the mouse as ‘PS/2’. 

Recognising an Intellimouse-style mouse

The Intellimouse format was introduced to support, among other features, the 
scroll wheel function. If your mouse has a scroll wheel, then it is likely to support 
the Intellimouse format. If you have a Microsoft mouse, then it will usually state 
that it is an Intellimouse on its underside label. 

Recognising an Intellimouse driver

Before hot plugging your X100 modules (or afterwards using only keyboard 
control), access the Windows Control Panel and select either the 

Mouse

 option 

(on Windows NT, 2000 and XP) or the 

System

 option (on Windows 95, 98, ME). 

Look for the name of the driver, which will usually include the words 

PS/2

 or 

Intellimouse

To restore mouse operation when hot plugging:

1  Carefully connect the X100 modules to the system and its keyboard, mouse, 

monitor, audio and serial device.

2  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

3  Enter the appropriate restore function code:   

• 

PS/2

 – press        

• 

IntelliMouse

 – press          

4  To exit configuration mode, press 

.

5  Move the mouse a short distance and check for appropriate on-screen 

cursor movement. If the mouse cursor darts erratically around the screen, 
then cease moving the mouse. This is an indication that the chosen restore 
function is incorrect. Try again using the other restore function.

Note: The restore functions predict the likely mouse resolution settings but 
may not restore the exact speed or sensitivity settings that were originally 
set. 

Microsoft and Logitech -specific mouse settings

In certain installations some Logitech mouse drivers may lose the action of the 
mouse buttons when used with the standard ‘Microsoft compatible’ signalling 
protocol used between the modules. To solve this problem, select the ‘Logitech 
compatible’ mouse signalling protocol.

To change mouse signalling protocols

1  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

2  Enter the appropriate protocol code:   

• 

Microsoft compatible

 – press        

• 

Logitech compatible

 – press          

3  To exit configuration mode, press 

Содержание AdderLink X100

Страница 1: ...Adder X100 User Guide REMOTE ADDER T O L O C A L P O W E R REMOTE ADDER T O L O C A L P O W E R...

Страница 2: ...the system 8 Special configuration Configuration 9 What are hotkeys 9 Entering using and exiting configuration mode 9 Password setting 10 Hot plugging and mouse restoration 11 Which restore setting do...

Страница 3: ...use connection Video connection Audio connection USB connection Three types of remote X100 modules are avilable and two types of local CAMs can be chosen Numerous combinations of local and remote modu...

Страница 4: ...tandard X100 with PS 2 style CAM X100 USB P Standard X100 with USB CAM X100A R Audio equipped X100 only no CAM X100A PS2 P Audio equipped X100 with PS 2 style CAM X100A USB P Audio equipped X100 with...

Страница 5: ...ists work well for Ethernet signals they can impose problems for the video signals transceived by the X100 modules The X100 modules send the red green and blue video signals on separate twisted pairs...

Страница 6: ...on the computer system 4 Attach the connector of the cable run to the socket of the CAM The other end of the cable run will attach to the remote X100 module PS 2 style keyboard Audio Video USB keyboar...

Страница 7: ...or to the light green coloured socket situated between the link connector and the power in socket 5 Insert the output connector of the power supply into the socket at the front edge of the X100 module...

Страница 8: ...1 OFF Normal operation ON Before power is applied Places the X100 module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in the Special config...

Страница 9: ...remote and local modules To lock the system 1 First set a password For further details please refer to the Password setting section in the Special configuration chapter 2 Simultaneously press the curr...

Страница 10: ...otkeys are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the X100 remote module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2...

Страница 11: ...ess the hotkeys by default and along with to enter configuration mode 2 Press followed by 3 Now enter your new password within the following constraints Passwords are NOT case sensitive Passwords may...

Страница 12: ...n it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot plugging your X100 modules or afterwards using only keyboard control access the...

Страница 13: ...n adjust the picture sharpness and brightness to improve the remote picture quality Video compensation is best carried out when viewing high contrast images with vertical edges such as black lines on...

Страница 14: ...ed video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied skew pattern or create...

Страница 15: ...advance the timing of the selected colour channel respectively On screen you will see a change in the position of the selected colour crosses or colour bars in relation to the other two 5 When the se...

Страница 16: ...ensure that the system is running an application that can display typed keys as screen characters e g a word processor or Windows Notepad The current firmware version will be written to the applicati...

Страница 17: ...odule directly to a computer system using a special cable The upgrade utility will update the firmware of the X100 and also temporarily transform it so that it can update the CAM unit Once completed t...

Страница 18: ...information Getting assistance Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support adder com Fax in the UK 01954 780...

Страница 19: ...wer extension cord with the X100 module make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord s ampere rating Also make sure that the total ampere r...

Страница 20: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Страница 21: ...edged Release 1 0a July 2006 Part No ADD00 Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation...

Отзывы: