Special configuration

Configuration

You can alter the way that the X100 modules operate to suit your requirements. 
This is done using the Configuration mode and you can affect the following 
settings: 

• 

Password.setting

 – allows you to lock the remote module to prevent 

unauthorised system access.

• 

Mouse.restoration.and.settings

 – allows you to restore mouse operation 

and also to change the mouse type.

• 

Video.compensation

 - sharpness & brightness

 – allows you to manually 

adjust the video image to ensure that it is crisp and bright.

• 

Skew.adjustment

 (X100AS only)

 – allows you to manually compensate for 

possible video errors introduced by long, uneven cable connections.

• 

Miscellaneous.settings

 – report firmware version and restore settings.

What are hotkeys?

Hotkeys are two normal keyboard keys that, when pressed simultaneously with a 
third key, signal to the X100 modules that you are sending a message specifically 
to them and not to the computer. The hotkeys are ordinarily 

 and 

, while 

a third keypress determines what you want the modules to do.
If the standard 

 and 

 hotkeys are also needed for computer tasks, you 

can change them for another combination using switches 2 and 3 on the X100 
remote module:

2 OFF
3 OFF  

Hotkeys = 

 and 

 (default setting)

2 OFF
3 ON  

Hotkeys = 

 and 

 

2 ON
3 OFF  

Hotkeys = 

 and 

2 ON
3 ON  

Hotkeys disabled 

Entering, using and exiting configuration mode

To enter and use configuration mode:

1  Simultaneously press the currently configured 

hotkeys (by default, 

 and 

) along with 

 

The three keyboard indicators (‘Num Lock’, ‘Caps 
Lock’ and ‘Scroll Lock’) will now begin to flash in 
sequence to show that you are in configuration 
mode. 

2  Press the first letter of the required configuration 

option, for instance  . 

All three keyboard indicators will illuminate 
continuously.

3  Press the number of the required configuration 

option, for instance  .  

The ‘Scroll Lock’ indicator will extinguish, leaving 
the ‘Num Lock’ and ‘Caps Lock’ indicators lit.

4  Press 

 to confirm your option.

The three keyboard indicators (‘Num Lock’, ‘Caps 
Lock’ and ‘Scroll Lock’) will now begin to flash in 
sequence again.

To exit from configuration mode:

1  Within configuration mode, the three keyboard indicators should be flashing 

in sequence to show that the module is ready to receive a new command.

2  Press 

The three indicators will return to their normal states.

 

Num

Loc

k

Caps

Loc

k

Scroll

Loc

k

Num

Loc

k

Caps

Loc

k

Scroll

Loc

k

HT

Содержание AdderLink X100

Страница 1: ...Adder X100 User Guide REMOTE ADDER T O L O C A L P O W E R REMOTE ADDER T O L O C A L P O W E R...

Страница 2: ...the system 8 Special configuration Configuration 9 What are hotkeys 9 Entering using and exiting configuration mode 9 Password setting 10 Hot plugging and mouse restoration 11 Which restore setting do...

Страница 3: ...use connection Video connection Audio connection USB connection Three types of remote X100 modules are avilable and two types of local CAMs can be chosen Numerous combinations of local and remote modu...

Страница 4: ...tandard X100 with PS 2 style CAM X100 USB P Standard X100 with USB CAM X100A R Audio equipped X100 only no CAM X100A PS2 P Audio equipped X100 with PS 2 style CAM X100A USB P Audio equipped X100 with...

Страница 5: ...ists work well for Ethernet signals they can impose problems for the video signals transceived by the X100 modules The X100 modules send the red green and blue video signals on separate twisted pairs...

Страница 6: ...on the computer system 4 Attach the connector of the cable run to the socket of the CAM The other end of the cable run will attach to the remote X100 module PS 2 style keyboard Audio Video USB keyboar...

Страница 7: ...or to the light green coloured socket situated between the link connector and the power in socket 5 Insert the output connector of the power supply into the socket at the front edge of the X100 module...

Страница 8: ...1 OFF Normal operation ON Before power is applied Places the X100 module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in the Special config...

Страница 9: ...remote and local modules To lock the system 1 First set a password For further details please refer to the Password setting section in the Special configuration chapter 2 Simultaneously press the curr...

Страница 10: ...otkeys are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the X100 remote module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2...

Страница 11: ...ess the hotkeys by default and along with to enter configuration mode 2 Press followed by 3 Now enter your new password within the following constraints Passwords are NOT case sensitive Passwords may...

Страница 12: ...n it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot plugging your X100 modules or afterwards using only keyboard control access the...

Страница 13: ...n adjust the picture sharpness and brightness to improve the remote picture quality Video compensation is best carried out when viewing high contrast images with vertical edges such as black lines on...

Страница 14: ...ed video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied skew pattern or create...

Страница 15: ...advance the timing of the selected colour channel respectively On screen you will see a change in the position of the selected colour crosses or colour bars in relation to the other two 5 When the se...

Страница 16: ...ensure that the system is running an application that can display typed keys as screen characters e g a word processor or Windows Notepad The current firmware version will be written to the applicati...

Страница 17: ...odule directly to a computer system using a special cable The upgrade utility will update the firmware of the X100 and also temporarily transform it so that it can update the CAM unit Once completed t...

Страница 18: ...information Getting assistance Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support adder com Fax in the UK 01954 780...

Страница 19: ...wer extension cord with the X100 module make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord s ampere rating Also make sure that the total ampere r...

Страница 20: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Страница 21: ...edged Release 1 0a July 2006 Part No ADD00 Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation...

Отзывы: