LTPE-UG-1017-01 Issue 1
Viewing System Status
UTU-731 List 1 and UTU-732 List 1
February 15, 2001
49
Field
Description
CRC-4 Errored
Seconds
(Cumulative)
The number of CRC-4 errors that were detected at the G.703 port
since error counters were last cleared. Turning CRC-4 mode on and
off clears the CRC-4 error counter.
Bipolar Violation
Seconds
(Cumulative)
The number of seconds in which bipolar violations were detected at
the G.703 port since error counters were last cleared.
Clear 24-Hour
History
The date and time that the 24-hour histories were last cleared are
displayed here. Enable this function by pressing
or
to
clear all 24-hour history counters (including HDSL). This action must
be confirmed by pressing
.
Table 19.
Fields Displayed in UTU-732 Monitor Interface Screens
Field
Description
Nx64k Port
Data & Clk Activity Displays the status of the data and clock signals at the Nx64k port at
one-second intervals. Asterisks (**) indicate an active line. Dashes
(- -) indicate an inactive line. Displayed fields are:
From DTE:
From DCE:
TT SD
ST RT RD
- - - -
** ** - -
Ctrl Signal State
Displays the status of the control signals at the Nx64k port at
one-second intervals. ON indicates an active line. OFF indicates an
inactive line. Displayed fields are:
From DTE:
From DCE:
RTS DTR RL LL
CTS DSR RLSD TM
OFF OFF OFF OFF
OFF OFF ON
OFF
Clear 24-Hour
History
The date and time that the 24-hour histories were last cleared are
displayed here. Enable this function by pressing
or
to
clear all 24-hour history counters (including HDSL). This action must
be confirmed by pressing
.
Table 18.
Fields Displayed in UTU-731 Monitor Interface Screens (Cont.)
L
ENTER
Y
L
ENTER
Y