System Configuration
LTPE-UG-1017-01 Issue 1
14
February 15, 2001
UTU-731 List 1 and UTU-732 List 1
Figure 5.
UTU-732 Virtual DIP Switch Parameter Settings (Nx64k Data Port)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Remote Console Access
(0 = allowed; 1 = blocked)
Local Unit Role
(0 = LTU; 1 = NTU)
Factory Defaults
HDSL Payload
(1 - 32) = 64 - 2048 kbps
Reserved
HDSL Rate Mode
(0 = manual; 1 = Nx64 auto)
Primary Timing Source (0 = Internal;
1 = External; 2 = Nx64k; 3 = HDSL)
Interface Type (0 = V36; 1 = X.21;
2 = RS-530; 3 = V35
1
2
3
4
5
6
7
8
SW
2
SW
3
SW1
SW4
Transmit Clock
(0 = External; 1 = Internal_Falling;
2 or 3 = I
_Rising)
nternal
Reserved
Reserved
CTS Signal
(0 = Off; 1 = Standard; 2 or 3 = On)
DSR Signal
(0 = Off; 1 = Standard; 2 or 3 = On)
RLSD Signal
(0 = Off; 1 = Standard; 2 or 3 = On)
LL/RL Signals (0 = disable; 1 = enable)
Reserved
When LED is lit:
Switch position is ON
= 1
(closed)
Switch position is OFF
= 0
(open)
LED Switch Settings
Green Red
1
2
3
4
5
6
7
8
SW5
<LOC> Loss of Clock Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
<MAR> Margin Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
<LOSW> Loss of Sync Word Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
1
2
3
4
5
6
7
8
SW6
<ES> Errored Seconds Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
Margin Alarm Threshold (0-15)
Reserved
Reserved
NTU Interface Type in Remote Program
Mode (green = Nx64k Data Port)
ES Alarm Threshold
(0-150 range, in multiples of ten.
For example: binary 0011 = 30;
1001 = 90; 1011 = 110)