LTPE-UG-1017-01 Issue 1
Installation
UTU-731 List 1 and UTU-732 List 1
February 15, 2001
9
The settings of DIP switch S700 are mapped to the next higher
number. For example, a DIP switch setting of 20 equals LTU
address 21. Refer to
Table 4.
Address Settings for LTU DIP Switch S700
LTU
Address
DIP Switch Position (x = ON)
(a) (b)
1
2
3
4
5
21
x
x
22
x
x
x
23
x
x
x
24
x
x
x
x
25
x
x
26
x
x
x
27
x
x
x
28
x
x
x
x
29
x
x
x
30
x
x
x
x
31
x
x
x
x
32
x
x
x
x
x
(a) DIP switch positions 6 and 8 are not used.
(b) Setting DIP switch position 7 to “ON” disables the
front-panel program mode. Configuration settings
become read-only and may be viewed by pressing
the PROG button and then the CURSOR button to
display each setting. The front-panel display will
indicate “b” (blocked) when the SW ON/OFF button is
pressed.