LTPE-UG-1017-01 Issue 1
System Configuration
UTU-731 List 1 and UTU-732 List 1
February 15, 2001
13
Figure 4.
UTU-731 Virtual DIP Switch Parameter Settings (G.703)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Remote Console Access
(0 = allowed; 1 = blocked)
Reserved
Local Unit Role
(0 = LTU; 1 = NTU)
Reserved
Reserved
Reserved
CRC4 Mode (0 = passthru;
1 = disable; 2 or 3 = enable)
CAS Mode
(0 = passthru; 1 = insert)
Reserved
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Idle Code (00....FF)
<LOS> Loss of Signal Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
SW
2
SW
3
SW1
SW5
SW4
<LFA> Loss of Frame Alignment Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
<RAI> Remote Alarm Indication Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
Reserved
1
2
3
4
5
6
7
8
<MAR> Margin Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
SW6
<LOSW> Loss of Sync Word Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
Margin Alarm Threshold (0-15)
1
2
3
4
5
6
7
8
<ES> Errored Seconds Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
SW7
<AIS> Alarm Indication Signal Alarm
(0 = disable; 1 = minor; 2 or 3 = major)
ES Alarm Threshold
(0-150 range, in multiples of ten)
When LED is lit:
Switch position is ON
= 1
(closed)
Switch position is OFF
= 0
(open)
LED Switch Settings
Green Red
HDSL Payload
(1 - 32) = 64 - 2048 kbps
Factory Defaults
NTU Interface Type in Remote
Program Mode (red = G.703)