LTPE-UG-1017-01 Issue 1
Viewing System Status
UTU-731 List 1 and UTU-732 List 1
February 15, 2001
45
Field
Description
Alarms
The Alarms field displays a list of all active alarms at each LTU/NTU and HDSL interface.
Possible Nx64k port alarms
LOC
Loss of incoming clock (TT) at the serial data port (only enabled
if the primary timing source is Nx64k).
Possible External Clock Alarms
LOC
Applies to loss of external clock when EXT timing is used. The
external clock was lost for the previous second. This alarm is reset
when the clock is active again.
Possible HDSL alarms
MAR1
Margin threshold has fallen below alarm threshold for the HDSL
interface.
ES1
Errored second count has exceeded alarm threshold for the HDSL
interface.
LOSW1
Loss of sync word for the HDSL interface. Remains active during
restart, but not a cold start.
Table 17.
Fields Displayed in UTU-732 Main Console Screen (Cont.)