4.10.4 RELIANCE IL SRU Remote CU Commands in lucDMC
Note
The commands may also be given using the Constant Current Regulator display menu. It is recommended to use the
lucDMC tool for commands as it is more complicated and time-consuming with the regulator display menu. Refer to
the respective section for more information.
Table 12: Segment commands — CU commands in lucDMC description
No.
Type Byte 3
Byte 2
Byte 1
Byte 0
Remarks
Implemented in
SRU ?
downward
compatible
1
GroupComm
and1 0x0F
Group 24-17
Group 16-09
Group 08-01
Bit = 0: group
off; bit = 1:
group on
Yes
Yes
Table 13: Lamp test commands — CU commands in lucDMC — description
No. Type Byte 3
Byte 2
Byte 1
Byte 0
Remarks
Implemented in
remote
downward
compatible
4
LamptestCommand
0x55
Standard 0x0F 0x11
0x00 or
remote
address
Remote(s) in ON state will
respond; with MA <> 0, only
addressed remote will respond,
now in period 1 for L1 and 2 for
L2; no response when filament
burnt
Yes
Yes
Group 0xF0
0x11
Segment
Address
Remote(s) in ON state with
provided segment address <> 0
will respond with the
appropriate time slot for L1
and/or L2; no response when
filament burnt or off
Yes
Yes
Special 0xFF
0x11
0x00 or
Module
Address
Remote(s) in ON and OFF state
of chosen lamp will respond;
with MA <> 0, only addressed
remote will respond, now in
period 1 for L1 and 2 for L2; no
response when filament burnt
Yes
Yes
Module test
0x55
0x11
0x00 or
Module
Address
Remote responds sending ON
and OFF state and answer if
filament burnt; RU2 responds
only for L1
Yes
Yes
Special single
lamp test
0x33
0x0C: L1,
0xC0: L2
0x00 or
Module
Address
Remote(s) in ON and OFF state
will respond; with MA <> 0, only
addressed remote will respond;
no response when filament
burnt
Yes
Yes
UM-5005, Rev. 004, 2020/08/06
77
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Intelligent Lighting Platform III
Страница 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Страница 2: ......
Страница 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 118: ......