Note
You can make sure all the changed parameters have been sent by hitting the refresh all parameters button in the top
right corner:
Figure 57: Refresh all parameters button — device settings
4.9.3 SRU Remote System Parameters
This section lists the values that can be set in the regulator for the RELIANCE IL for system parameterization using lucDMC.
Table 10: SRU remote system parameters description
Data type
Designation
Functionality
Value range
Default
u8
u8IntegrationBase
Integration set value
1-255
50
u8
u8FallingSlopeThr
Falling slope threshold
0-255
60
u16
u16HWCalibrationLimit
Limit of half cycle calibration
0-1000
500
u8
u8HWCalibrationStep
Calibration step
0-255
10
u8
u8DynAverageSize
Dynamic average size
1-255
8
u16
u16AdcZeroThr
Gradient dynamic threshold to RMS
1-512
224
u8
u8DynThr
Noise distance to RMS
1-255
45
u8
u8ZeroDelay
Set integral to 0
0-255
50
u8
u8DiffThr
Dynamic threshold to RMS Current
50-255
100
u8
u8DiffThrSYNC
Dynamic threshold to RMS current (SYNC)
50-255
80
u16
u16FbFetDuration_us
Duration of SCROLL feedback in
microseconds
0-4000
3000
u16
u16RelayFetDelay_us
Delay between relay and FET in
microseconds
0-1000
0
u16
u16FbLowerLoadVoltageThr
Lower threshold to detect a shorted load in
mV RMS, 0 = no detect
0-50000
740
u16
u16FbUpperLoadVoltageThr
Upper threshold to detect a shorted load in
mV RMS, 0 = no detect
0-50000
50000
u8
u8FbHighPowerMode
0 = 230W, 1 = 315 W
0, 1
0
u8
u8CMNoOfVoltageTripsFO
Number of overvoltage trips until remote
detects a broken load
1-255
8
u8
u8PulseDiffThrAddValue
SCROLL pulse offset
0-255
35
u8
u8FactorFbVsCurrent10
Factor for FET duration in percent (5.4A >=
current > 4.8A)
10-100
80
u8
u8FactorFbVsCurrent30
Factor for FET duration in percent (current >
5.4A)
10-100
60
4.9.4 Parameterizing the CCRE for Lamp Failure Measuring using lucDMC
This section does not explain how a series circuit without RELIANCE IL is commissioned. For further information about
commissioning of a series circuit in general contact the ADB SAFEGATE service team and check
Planning data, restrictions and performance data
RELIANCE Intelligent Lighting
Operation
70
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Intelligent Lighting Platform III
Страница 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Страница 2: ......
Страница 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 118: ......