B-11
Troubleshooting Tips
■
It’s not clear what should be done from the Failover Setup
Menu. How do I configure the ports?
To install the Duralink64 v5.x Failover software on NetWare
v4.2, v5.0, or v5.1, use
configsf
from the Duralink64 v5.x
NetWare CD. At the Main Menu, select Failover, then,
Configure Ports
, Set Failover Pairs, Configure Protocols,
Install Software,
then Save and Exit. Make sure you follow this
sequence and end with Save and Exit. The Save and Exit
function modifies the
autoexec.ncf
file so that the Failover
software is loaded each time you boot the server.
■
How do I install Duralink64 v5.x Failover or Port
Aggregation if I currently have the Duralink64 v5.x Standard
drivers installed?
The
setupsf
file is used only when installing and uninstalling
Duralink64 v5.x Failover or Port Aggregation software. The
configsf
file is also used after installation for changing the
failover configuration.
■
Does Duralink64 v5.x support Novell’s 32-bit client for
Windows 98, Windows 2000, or Windows NT?
Yes. However, connecting clients to the NetWare Duralink64
server requires the NDIS driver. Do not use an ODI driver. See
the User's Guide Windows 98, Windows 2000, or Windows NT
Installation sections for details.