5.5
REPLACING
THE
POWER
PCB
Place the machine onto one side which will expose the service cover
panel, remove the 2 screws and the panel with the power PCB attached
will come away, remove the PCB cover and faulty PCB and replace with
a new one.
5.6
REPLACING
SENSORS
When replacing a sensor the old one will need to be removed and the
new one fitted to the PCB or mounting. Various screws have to be
removed to gain access to the sensors.
The START sensor can be changed after removing the note feeder
assembly as explained in section 5.1
The BATCH sensor can be changed following the removal of the 2 x
screws on the front underside of the machine. The new sensor will have
to be fixed using hot melt glue.
The UV, MG and also the LEFT and RIGHT sensors can be changed by
accessing them from the front and also from the top of the machine.
The display unit will need to be pulled forward to expose the top part
for access.
5.7
SENSOR
POSITION
PICTURE