background image

 

 

 

Adam Equipment Company 2012

 

 

ADAM  EQUIPMENT

  is  an  ISO  9001:2008  certified  global  company  with  more  than  35  years 

experience in the production and sale of electronic weighing equipment.  

 

Adam products are predominantly designed for the Laboratory, Educational, Health and Fitness, 

retail and Industrial Segments. The product range can be described as follows: 

 

-Analytical and Precision Balances 

-Compact and Portable Balances 

-High Capacity Balances 

-Moisture analysers / balances 

-Mechanical Scales  

-Counting Scales 

-Digital Weighing/Check-weighing Scales 

-High performance Platform Scales  

-Crane scales 

- Health and Fitness Scales 

-Retail Scales for Price computing 

For a complete listing of all Adam products visit our website at www.adamequipment.com 

 

 

© Copyright by Adam Equipment Co. Ltd.  All rights reserved.  No part of this publication may be reprinted or 

translated in any form or by any means without the prior permission of Adam Equipment. 

Adam Equipment reserves the right to make changes to the technology, features, specifications and design of 

the equipment without notice. 

All  information  contained  within  this  publication  is  to  the  best  of  our  knowledge  timely,  complete  and 

accurate  when  issued.    However,  we  are  not  responsible  for  misinterpretations  which  may  result  from  the 

reading of this material. 

The latest version of this publication can be found on our Website. 

 

www.adamequipment.com 

Содержание NCSA 20plus

Страница 1: ...Adam Equipment Company 2012 Adam Equipment NCSA 20plus Service Manual P N 7 00 6 6 0247 Revision A August 2012 ...

Страница 2: ...VEL 6 3 1 PARAMETER SETTING TABLE 6 4 0 ERROR MESSAGES CODES AND SOLUTIONS 7 4 1 SENSOR ERROR TABLE 7 4 2 BANK NOTE ERROR TABLE 7 5 0 SERVICE INFORMATION 8 5 1 REPLACING THE FEED ROLLERS 8 5 2 REPLACING THE DRIVE BELTS 9 5 3 REPLACING THE MAIN PCB 10 5 4 REPLACING THE DISPLAY PCB 10 5 5 REPLACING THE POWER PCB 11 5 6 REPLACING SENSORS 11 5 7 SENSOR POSITION PICTURE 11 5 8 REPLACING OTHER PARTS 12 ...

Страница 3: ...e BATCH key to enter the BATCH mode which enables you to select the required quantity of notes to be counted ADD Press this key to enable accumulation of the counted notes Press this key to increase the quantity in the BATCH display It can also be used to select settings in the parameter section Press this key to decrease the quantity in the BATCH display It can also be used to select settings in ...

Страница 4: ...he notes into the guides at the rear of the machine and the counter will feed through the required amount and stop The Main display should display and match that of the BATCH display with the correct amount of notes being in the holder at the front of the machine When the notes are removed the counting automatically resumes and feeds through the remaining notes until the required figure is met aga...

Страница 5: ...play will reset to 0 Once the notes have been fed through the BATCH display will show the quantity of this last count only and the Main display will show the total of the two counts Continue like this until all of the notes are counted When finished the Main display will show you the total of all counting processes that have been made The BATCH display will always show the last quantity of notes c...

Страница 6: ...ounting When a counterfeit note is detected by the UV sensor the counting process will stop the counter will BLEEP and the error message E2 will be displayed until the note is removed from the holder Remove the counterfeit note and press START to continue counting The last note in the holder will always be the counterfeit one The MG and UV functions can be de activated by pressing the MG and or UV...

Страница 7: ... its setting Once settings have been made press the START key to return to normal counting 3 1 PARAMETER SETTING TABLE CODE FUNCTION AVAILABLE SETTINGS DEFAULT OP A UV SENSITIVITY OFF AND 1 10 1 LOWEST 10 HIGHEST 5 OP B MG SENSITIVITY OFF AND 1 10 1 LOWEST 10 HIGHEST 5 OP D SIZE DETECTION YES NO YES OP E AUTOMATIC OR MANUAL YES AUTOMATIC NO MANUAL YES OP U INCLUDE DUBIOUS NOTE IN TOTAL YES NO YES ...

Страница 8: ... PROBLEM 4 2 BANK NOTE ERROR TABLE CODE ERROR SOLUTION E 1 HALF NOTE DETECTED REMOVE NOTE AND PRESS START E 2 DUBIOUS NOTE DETECTED BY UV SENSOR REMOVE THE NOTE AND PRESS START CHECK THE UV SENSITIVITY SETTING E 3 DUBIOUS NOTE DETECTED BY MG SENSOR REMOVE THE NOTE AND PRESS START CHECK THE MG SENSITIVITY SETTING E 5 DUBIOUS NOTE DETECTED BY SIZE DETECTION SENSOR REMOVE THE NOTE AND PRESS START E 9...

Страница 9: ...lacement of parts may be necessary when faults occur the error codes in table 4 1 help determine where some of the faults may lie and the following information is a guide how to remove and replace them 5 1 REPLACING THE FEED ROLLERS Unscrew the note feeder adjusting screw as far as you can and pull hard towards you on the note feeder assembly The assembly should come out exposing the feed rollers ...

Страница 10: ...sition the shaft replace both circlips and re fit the drive belt if removed Re fit the two side covers note feeding assembly and guide 5 2 REPLACING THE DRIVE BELTS Remove the right side cover to expose the drive assemblies Pull the old drive belts from the wheels and replace with a new one making sure that the drive belts are situated correctly on the wheels then replace the cover ...

Страница 11: ...w the speed sensor and disconnect the cable from the PCB Fit the new sensor fasten securely and re connect the cable to the PCB 5 4 REPLACING THE DISPLAY PCB Lift the handle and lean it towards the rear of the counter then from the rear lift the display housing towards the front Remove the 5 x screws to expose the display PCB Remove the 6 x PCB fixing screws and connector from the PCB and replace ...

Страница 12: ...PCB or mounting Various screws have to be removed to gain access to the sensors The START sensor can be changed after removing the note feeder assembly as explained in section 5 1 The BATCH sensor can be changed following the removal of the 2 x screws on the front underside of the machine The new sensor will have to be fixed using hot melt glue The UV MG and also the LEFT and RIGHT sensors can be ...

Страница 13: ...Y PCB 7 00 4 0 0128 NCSA 20plus ON OFF SWITCH 7 00 4 0 0129 NCSA 20plus LARGE MOTOR 7 00 4 0 0130 NCSA 20plus SMALL MOTOR 7 00 2 3 0009 NCSA 20plus FEED ROLLERS SET OF 7 00 2 3 0010 NCSA 20plus LARGE DRIVE BELT 7 00 2 3 0011 NCSA 20plus SMALL DRIVE BELT 7 00 1 0 0293 NCSA 20plus LEFT AND RIGHT SIDE SENSOR x2 7 00 1 0 0294 NCSA 20plus MG SENSOR 7 00 1 0 0295 NCSA 20plus UV SENSOR 7 00 1 0 0296 NCSA...

Страница 14: ...13 Adam Equipment Company 2012 MAIN PCB SPEED SENSOR DRIVE BELTS ...

Страница 15: ...14 Adam Equipment Company 2012 POWER PCB MOTORS ...

Страница 16: ...l packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements a...

Страница 17: ...Adam Equipment Company 2012 ...

Страница 18: ...Adam Equipment Company 2012 ...

Страница 19: ...ce to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved b...

Страница 20: ...Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technol...

Отзывы: