TYPE C CHIMNEY CONNECTION
• C13 :
concentric horizontal connection
• C33(x): concentric vertical connection
• C53(x): parallel chimney connection
• C63(x): concentric vertical connection without terminal
(Only in Germany and Luxemburg)
Th
e maximum pressure drop in flue pipe (air inlet + flue gas outlet)
cannot
exceed 100 Pa - see table below indicating the pressure drop for each
of the components).
A = fresh air supply
HeatMaster®
B = flue gas
30N / 60N / 70N
100 N
A
B
A
B
Ø 80
Ø 150 Ø 100 Ø 150
1m straight pipe
6
1
6
2
90° elbow
15
2
15
5
45° elbow
6
1
6
2
Condensate recovery container
_
2
_
4
Terminal
20
10
20
20
This table is based on ACV equipment and cannot be applied as a rule
In the case of a concentric connection, the total flue pipe
length is limited to 6 meters.
A condensation outlet connected to the sewer must be
fitted close to the boiler to prevent the condensation
products from the chimney from running into the boiler.
To avoid condensation water running out of the terminal,
all horizontal flue ducts must be installed with a slight
downward slope toward the boiler.
≥ 2,2 m
150 min.
120
I
O
I
O
I
O
I
O
I
O
I
O
C
33(x)
C
33(x)
C
53(x)
B
23
B
23P
C
13
C
13
TECHNICAL CHARACTERISTICS
Содержание HeatMaster 100 N
Страница 16: ...EN FR RU PL DE IT ES NL EN 15 664Y5400 B INSTALLATION 2 x 1 2 3 4 5 6...
Страница 21: ...EN FR RU PL DE IT ES NL EN 20 664Y5400 B...
Страница 22: ...EN FR RU PL DE IT ES NL EN 21 664Y5400 B...
Страница 23: ...EN FR RU PL DE IT ES NL EN 22 664Y5400 B...
Страница 24: ...EN FR RU PL DE IT ES NL EN 23 664Y5400 B...
Страница 25: ......
Страница 26: ......
Страница 27: ......