USER'S GUIDE
USING THE BOILER
Make sure to have your installation inspected and
maintained, if required, at least once a year by an
approved and qualified engineer. More frequent
servicing may be required depending on boiler use. If
this is the case, consult your installer for advice.
Starting the burner:
In normal operation, the burner starts automatically
as soon as the boiler temperature drops below the set
temperature.
GETTING FAMILIAR WITH THE CONTROL PANEL
The user must not attempt to gain access to the components inside the
control panel.
• Master switch
Is used to turn the HeatMaster® on or off.
• Control thermostat - 60-90 °C
When using the HeatMaster® as a hot water generator only, the
temperature can be set between 60 °C and 90 °C. If the HeatMaster®
is used for both domestic hot water (DHW) and central heating, the
control thermostat would normally be set at 80 °C to achieve optimum
operating conditions.
• Summer/winter switch
Is used to turn the heating pump (if fitted) on or off.
• Manual reset high limit thermostat
If the boiler temperature exceeds 103 °C, this safety device will activate
and the high temperature indicator will light up. To reset - first allow the
boiler to cool to below 60 °C, unscrew the cap and press the reset button
using a pencil or similar pointed device, then reinstall the cap. If the fault
persists, turn the boiler off and call a service engineer.
• Daily timer
Allows the HeatMaster® to be turned on and off at specific moments of
the day and operates on a 24 hour sequence. A series of white tabs are
set around the timer, each tab corresponding to a 15 minute switching
period. To set the timer, simply push outwards the number of tabs
required for ON period.
Remember:
Tab in
= HeatMaster® OFF
Tab
out
=
HeatMaster® ON
• Temperature and pressure gauge
This gauge indicates both the temperature of the HeatMaster® and the
pressure within the primary circuit. The temperature should not exceed
90 °C - if it does, switch the boiler off and check the thermostat setting.
If the fault persists, call an engineer. The pressure should not fall below
1 bar, if it does, please see the ‘Heating System Pressure’ paragraph
further in this section.
• Low primary water pressure indicator
If this indicator lights up, the primary circuit of the HeatMaster®
requires topping up with water. Please see the ‘Heating System
Pressure’ paragraph later in this section.
1. Burner safety cutout warning indicator
2. Low primary water pressure indicator
3. High limit thermostat indicator
4. Temperature and pressure gauge
5. Control thermostat
6. Daily timer
7. Manual reset high limit thermostat
8. Master switch
9. Summer/winter switch
HeatMaster® 30 N and 60 N Control Panel
I
O
1
4
5
3
2
7
6
8
9
HeatMaster® 70 N and 100 N Control Panel
I
O
1
4
5
3
2
7
6
8
9
Содержание HeatMaster 100 N
Страница 16: ...EN FR RU PL DE IT ES NL EN 15 664Y5400 B INSTALLATION 2 x 1 2 3 4 5 6...
Страница 21: ...EN FR RU PL DE IT ES NL EN 20 664Y5400 B...
Страница 22: ...EN FR RU PL DE IT ES NL EN 21 664Y5400 B...
Страница 23: ...EN FR RU PL DE IT ES NL EN 22 664Y5400 B...
Страница 24: ...EN FR RU PL DE IT ES NL EN 23 664Y5400 B...
Страница 25: ......
Страница 26: ......
Страница 27: ......