TECHNICAL CHARACTERISTICS
COMBUSTION CHARACTERISTICS
HEATMASTER® WITHOUT BURNER
HeatMaster®
30 N
HeatMaster®
60 N
HeatMaster®
70 N
HeatMaster®
100 N
Maximum input
kW
34.9
69.9
69.9
107.0
Maximum output
kW
31.4
63.0
63.0
96.3
Maintenance loss at 60% of rated value
%
0.69
0.57
0.60
0.65
HEATMASTER® PROVIDED WITH A BG 2000-S BURNER
HeatMaster®
30 N
+ BG 2000-S / 35
HeatMaster®
60 N
+ BG 2000-S / 60
HeatMaster®
70 N
+ BG 2000-S / 70
HeatMaster®
100 N
+ BG 2000-S / 100
Maximum input (PCI) - [G20 - G25]
kW
34.9
69.9
69.9
107.0
Maximum input (PCI) - [G31]
kW
NC
69.9
69.9
110.0
Maximum output - [G20 G25]
kW
31.4
63.0
63.0
96.3
Maximum output - [G31]
kW
NC
63.0
63.0
99.0
Rated efficiency
%
90.0
90.1
90.2
90.5
Efficiency at 30% load
%
95.0
96.6
96.7
96.4
Combustion efficiency
%
92.0
91.2
91.5
92.1
Gas: G20 - 20 mbar
I2E(S) // I2H // I2Er // I2ELL // I2E // I2E(R)
Flow rate
m
3
/h
3.70
7.40
7.40
11.32
Gas: G25 - 25 mbar
I2L
Flow rate
m
3
/h
—
8.60
8.60
13.17
Gas: G31 - 37/50 mbar
I3P
Flow rate
m
3
/h
1.43
2.86
2.86
4.50
HYDRAULIC CHARACTERISTICS
HeatMaster®
30 N
HeatMaster®
60 N
HeatMaster®
70 N
HeatMaster®
100 N
Heating Connection [F]
Ø
1”1/2
1”1/2
1”1/2
1”1/2
DHW Connection [M]
Ø
3/4”
3/4”
1”
1”
DHW tank heat exchanger surface
m2
2.46
2.46
3.14
3.95
Primary circuit water pressure drop (∆T = 20K)
mbar
27
54
46
83
Total capacity
L
162
162
239
330
Primary circuit capacity
L
82
82
108
130
DOMESTIC HOT WATER PERFORMANCE *
OPERATING CONDITIONS AT 90°C
HeatMaster®
30 N
HeatMaster®
60 N
HeatMaster®
70 N
HeatMaster®
100 N
Peak flow at 40°C [∆T = 30 K]
L/10’
380
474
646
905
Peak flow at 45°C [∆T = 35 K]
L/10’
320
378
543
777
Peak flow at 40°C [∆T = 30 K]
L/60’
1130
1942
2133
3172
Peak flow at 45°C [∆T = 35 K]
L/60’
963
1656
1794
2680
Constant flow at 40°C [∆T = 30 K]
L/h
900
1835
1835
2776
Constant flow at 45°C [∆T = 35 K]
L/h
772
1573
1573
2379
Reheat time at 60°C
minutes
18
9
16
13
* for DHW temperatures > 45°C (∆T > 35K), please contact ACV
The temperature of the domestic hot water can be adjusted up to 90 °C in the boiler. However, the temperature of the domestic hot
water at the drawing point must comply with local regulations.
(E.g. in Belgium, the maximum DHW water temperature at a drawing point
must be 75°C for boilers < 70 kW).
For special applications, please contact ACV.
BURNER
All the HeatMaster® N boilers can be equipped with an oil or gas burner available on the market.
The HeatMaster® N can be factory fitted with a low NOx premix gas burner (BG 2000-S).
Содержание HeatMaster 100 N
Страница 16: ...EN FR RU PL DE IT ES NL EN 15 664Y5400 B INSTALLATION 2 x 1 2 3 4 5 6...
Страница 21: ...EN FR RU PL DE IT ES NL EN 20 664Y5400 B...
Страница 22: ...EN FR RU PL DE IT ES NL EN 21 664Y5400 B...
Страница 23: ...EN FR RU PL DE IT ES NL EN 22 664Y5400 B...
Страница 24: ...EN FR RU PL DE IT ES NL EN 23 664Y5400 B...
Страница 25: ......
Страница 26: ......
Страница 27: ......