11.Monitoring statistics line concentration box and monitoring statistics software
5
10. Wireless receiver (HWR-1)
Cooperating with the wireless transmitter. When an extension calls, the wireless
transmitter will automatically transmit the calling extension number to nursing
personnel equipped with the wireless receiver.
Usually carried by walking nurses. When an extension calls the mainframe, there
will be prompt, and the extension number will be displayed.
Power supplied by battery, with a low power consumption.
The effective receive radius for the wireless device is 50 meters.
Dimensions:63x47x28mm(LxWxH)
7. Door lamp
Generally installed outside the ward to facilitate nurses in the corridor in observing.
When the bed calls the nurse station, the door lamp of the ward will blink.
When the ward bed releases the call or when the nurses talks with the patient, the
door lamp outside the ward will go out.
Generally speaking, only one lamp is required for one ward.
Red and black wires
(connected to the red and
black wires on extensions)
8. External power supply
If it is necessary for the extension to realize broadcast and connecting to the
transfusion alarm device, the external power supply is added to the
extension for power supply.
Each external power supply can supply power for 30 extensions.
When the number of extensions exceeds 30, an additional power supply is required.
Output parameters:14V 2.5A
Dimensions: 87x71x39mm(LxWxH)
9. Wireless transmitter (HWT-1)
Cooperating with the wireless receiver. When an extension calls, the wireless
transmitter will automatically transmit the calling extension number to nursing
personnel equipped with the wireless receiver.
Generally installed nearby nurses, so as to ensure reliable receive distance
of the wireless receiver.
Independent power supply shall be provided.
Effective wireless transmitting radius of 50 meters.
Working voltage: DC15-18V
Maximum working current:
2500mA
Dimensions: 140x116x35mm(LxWxH)
A, B, +18V and COM wires (wires A and B are
connected with binding posts A and B, +18V
and COM to negative and positive poles of
external power supply)
Optional. It has to cooperate with the monitoring statistics software (model: HWS-1).
Connected to 232 serial ports of the computer, it can monitor and collect statistics
from 32 mainframes at the same time.
Line concentration box power supply, model: HWR-x 12V500mA.
One three-core wire is used for connection to each mainframe.
Installed in the computer, it can collect statistics, perform analysis and print statements.
User friendly interface and clear data recording, it is conducive to service management
and supervision.
Information and data synchronization. Able to display the information status of
each extension synchronously (namely, standby, call and talk).
Complete statistics, and generation of statement in Access format. Able to display
the extension's call origination time, call duration, talk start time, and talk
duration, able to collect statistics of the most recent call and talk records, able to
query all call and talk records of a certain extension, and able to query call and talk
records of all extensions on a daily or monthly basis.
Free software
No.10 CALL