4. Waterproof  switch (HB-1)

Connected to 1 and COM connecting terminals 
of the two-core bus of the mainframe

5. Transfusion  alarm device (HA-1)

Able to cooperate  with HI-1/2 extension  or operate independently  (an 
additional power supply  is required).
Clamped onto the  transfusion tube, it  has not contact  with transfusion. Simple 
one-key operation.
Beep will emit when transfusion is completed; at the same time, the transfusion 
tube will be automatically blocked.
When it cooperates  with the HI-1/2  extension, alarm signals  can be sent  to the 
mainframe of the nurse station through the extension. There is LED display on the 
mainframe, and the voice announcement 'XX transfusion completed' will be played.
Working voltage:                          DC12V                        
Maximum working current:         450mA
Dimensions:                                 

                                   

60x70x65mm(LxWxH)

Connected to the transfusion alarm interface of the extension

Corridor displays include  dot matrix single-sided  display, dual-side  corridor display HD-1/HD-2,  dot matrix 
single-side, and dual-side  corridor display HD-3/HD-4.
Simple installation, only  one three-core wire  is required for  direct connection with  the mainframe for  convenient 
check.
Generally, it is installed in the corridor to facilitate nursing personnel in the corridor in observing.
The dot matrix display can display the calling extension number and nursing grade, in case of no call, it is able to 
display year, month, date, time, 'Please keep quiet!' or etiquette phrases.
Independent power supply shall be provided.
Working voltage:DC11-18V
Dimensions:(Single-side and small)478X140X35mm(LxWxH), (Dual-side and big)1048X140X35mm(LxWxH)
                      (Single-side and small)478X140X70mm(LxWxH), (Dual-side and big)1048X140X70mm(LxWxH)

 

2

1

  Installation support                                                

  

Connecting wire(A,  B,  +12V/14V,  COM)

        

Dot matrix display area

3

3

6. Corridor displays  (HD-1, HD-2, HD-3, HD-4)

Dot matrix displays  (HD-1, HD-2)

1

3 2

A, B, +12V, COM wire

1

3

Dot matrix displays (HD-3, HD-4)

A, B, +12V, COM wire

1

2

1

3

It is generally installed in the toilet of the ward for alarm when there is an 
emergency of patients in the toilet.
Two alarm modes are available, namely, pulling cord and pressing key.
Water balls and fog in the toilet shall be prevented, so as to ensure the normal 
use of the switch.
In case of emergency alarm in the toilet, there will be voice prompt and number 
display on the mainframe.
When the switch is in the alarm status, the indicator light on the switch will blink, 
if the indicator light goes out, it means that the nurse station has received the 
alarm signal.

Dimensions:86x86x15mm(LxWxH)

Содержание HC-30

Страница 1: ...ystem profile Technical specifications System installation System setup Operation instructions Matters for attention Troubleshooting Service commitment Hospital nursing intercom system installation an...

Страница 2: ...e for example alarmsound flashing light and voice announcement XX transfusion completed Three level nursing Threelevels of nursing namely special high and common can be seton the mainframe according t...

Страница 3: ...ht 2 The mainframe haveChinese LCD displaywith menu functionsand operations asa result theoperation is more convenient and simpler and theproduct is ableto display variousstatuses date andtime Only on...

Страница 4: ...to callthe mainframe There is atransfusion alarm interfaceon the extensionthat can cooperatewith the transfusionalarm device When transfusion is completed the extension reportsalarms to themainframe a...

Страница 5: ...talled inthe corridor tofacilitate nursing personnelin the corridorin observing The dot matrixdisplay can displaythe calling extensionnumber and nursinggrade in caseof no call it is ableto display yea...

Страница 6: ...th thewireless receiver When an extensioncalls the wireless transmitter will automaticallytransmit the callingextension number tonursing personnel equipped withthe wireless receiver Generally installe...

Страница 7: ...pecificwiring method pleaserefer to thefollowing Preparation for extensiononline coding Connectone pair ofwhite and blackwires on theextension or the waterproof switch respectivelyonto the two corebus...

Страница 8: ...e 5 Connection betweenthe door lampand extension take theextensions inside thesame ward as an example 1 Connect thered and blackwires of thedoor lamp ontothe red andblack wires ofthe extension accordi...

Страница 9: ...n the mainframe Corridor display 3P 2P 8 Connection betweenmonitoring statistics lineconcentration box monitoringstatistics software computer andmainframe A Insert the power cord into the line concent...

Страница 10: ...tomatically detectextensions The mainframechecks extensions oneby one fromextension 1 theextension is normal andthe indicator lightblinks once ifthere is anyextension wrong orthe channel isnot connect...

Страница 11: ...nursing station Mainframe Level 2management nursing station Power source Line concentration box Corridor display Power source Power source Power source To list of patients To extension outside power s...

Страница 12: ...vel is 01 four panes ofvolume for theday twopanes for volumeat night andfour panes for hands free talkvolume 4 The startupalarm time is00 00 note thisfunction setup isnot activated andthe mainframe fo...

Страница 13: ...and there isa voice announcement reporting the extensionnumber and calllevel To remove thehigh level nursingsetup for anextension just select the routing switchof the channelin the specialnursing set...

Страница 14: ...Call VOL FUNCTION MNTR PWR FUNCTION MNTR ALL FUNCTION MNTR PWR FUNCTION MNTR ALL Volume FUNCTION MNTR Press the or key to enter setup to enter setup Press or key to select the volume Press or key to s...

Страница 15: ...odel HC After the previous step press the Function key to enter the mainframe level setup Tiering Setup Model HC 10 Ward bed setup takeextension 13 setto bed 03of ward 204as an example Sickbed Setup M...

Страница 16: ...vious item press the Function key to enter the forwarding upward duration setup Tier Transfer Setup FUNCTION MNTR ALL Model HC PWR 11 Online coding setup e g code theextension as No 1 extension After...

Страница 17: ...at the sametime for groupcall Every five channelsform one group namely 1 5 6 10 11 15 as one group Tocall a groupin group call press down the firstchannel of routingswitch of thegroup for example 1 6...

Страница 18: ...ompanywill try itsbest to meetyour needs This product canonly be maintainedby our company strained professional personnel The rear coverof the mainframe shall notbe opened withoutour company s authori...

Страница 19: ...e key is pressed Unable to operatenormally after startup The extension cancall the mainframe however it is difficult for themainframe to choose anextension Bus disconnection 1 Extension damaged 2 Conn...

Отзывы: