6. 

Matters for attention

1. Mainframe

17

2. Extension

3. Corridor display

To be free from system faults, avoid using the product in places with major humidity and temperature fluctuation, 
direct blow by cool and warm wind, and excessive dust.
The duration after each time of power on and off shall be more than one minute, especially in the talk status or 
extension call status. Shutdown during talk is strictly forbidden.
Power sockets shall be securely grounded, with secure sockets.
Please unplug the power plug in case of long time of disuse.
In case of startup with a long time of interval, be sure that the internal clock is in compliance with the current time.
If there is any smoke, foreign smell and other abnormal situations with the mainframe, immediately power off, 
check and troubleshoot it.
Corridor display, wireless transmitter, wireless receiver, transfusion alarming device, and portal light are optional, 
and customers can choose to install them or not according to needs.
If you have any special needs, please communicate with our company's sales people when you place an order, 
and our company will try its best to meet your needs.
This product can only be maintained by our company's trained professional personnel. The rear cover of the 
mainframe shall not be opened without our company's authorization. Otherwise, our company is not responsible 
for warranty.

The location for the extension shall be convenient for patients to operate. Patients are able to use a handheld caller 
for calling and intercom.
When special nursing extensions, high grade extensions and common extensions call the mainframe at the same 
time, the mainframe will only broadcast the special nursing extension number.
The extension can serve as a broadcasting device. To realize broadcast and transfusion alarming, an additional 
two-core wire shall be connected to external power supply. When the number of extensions is within 30, an 
additional power supply is required; when the number of extensions is over 30, two additional power supplies are 
required.

The corridor display is usually installed inside the corridor to facilitate nursing personnel in observation.
Avoid using the product under sunshine or other strong light sources, which may otherwise affect the display effect.
When the power supply is connected, the dot matrix display will display year, month, date, time and 'Please keep 
quiet!' in a rolling manner.

Содержание HC-30

Страница 1: ...ystem profile Technical specifications System installation System setup Operation instructions Matters for attention Troubleshooting Service commitment Hospital nursing intercom system installation an...

Страница 2: ...e for example alarmsound flashing light and voice announcement XX transfusion completed Three level nursing Threelevels of nursing namely special high and common can be seton the mainframe according t...

Страница 3: ...ht 2 The mainframe haveChinese LCD displaywith menu functionsand operations asa result theoperation is more convenient and simpler and theproduct is ableto display variousstatuses date andtime Only on...

Страница 4: ...to callthe mainframe There is atransfusion alarm interfaceon the extensionthat can cooperatewith the transfusionalarm device When transfusion is completed the extension reportsalarms to themainframe a...

Страница 5: ...talled inthe corridor tofacilitate nursing personnelin the corridorin observing The dot matrixdisplay can displaythe calling extensionnumber and nursinggrade in caseof no call it is ableto display yea...

Страница 6: ...th thewireless receiver When an extensioncalls the wireless transmitter will automaticallytransmit the callingextension number tonursing personnel equipped withthe wireless receiver Generally installe...

Страница 7: ...pecificwiring method pleaserefer to thefollowing Preparation for extensiononline coding Connectone pair ofwhite and blackwires on theextension or the waterproof switch respectivelyonto the two corebus...

Страница 8: ...e 5 Connection betweenthe door lampand extension take theextensions inside thesame ward as an example 1 Connect thered and blackwires of thedoor lamp ontothe red andblack wires ofthe extension accordi...

Страница 9: ...n the mainframe Corridor display 3P 2P 8 Connection betweenmonitoring statistics lineconcentration box monitoringstatistics software computer andmainframe A Insert the power cord into the line concent...

Страница 10: ...tomatically detectextensions The mainframechecks extensions oneby one fromextension 1 theextension is normal andthe indicator lightblinks once ifthere is anyextension wrong orthe channel isnot connect...

Страница 11: ...nursing station Mainframe Level 2management nursing station Power source Line concentration box Corridor display Power source Power source Power source To list of patients To extension outside power s...

Страница 12: ...vel is 01 four panes ofvolume for theday twopanes for volumeat night andfour panes for hands free talkvolume 4 The startupalarm time is00 00 note thisfunction setup isnot activated andthe mainframe fo...

Страница 13: ...and there isa voice announcement reporting the extensionnumber and calllevel To remove thehigh level nursingsetup for anextension just select the routing switchof the channelin the specialnursing set...

Страница 14: ...Call VOL FUNCTION MNTR PWR FUNCTION MNTR ALL FUNCTION MNTR PWR FUNCTION MNTR ALL Volume FUNCTION MNTR Press the or key to enter setup to enter setup Press or key to select the volume Press or key to s...

Страница 15: ...odel HC After the previous step press the Function key to enter the mainframe level setup Tiering Setup Model HC 10 Ward bed setup takeextension 13 setto bed 03of ward 204as an example Sickbed Setup M...

Страница 16: ...vious item press the Function key to enter the forwarding upward duration setup Tier Transfer Setup FUNCTION MNTR ALL Model HC PWR 11 Online coding setup e g code theextension as No 1 extension After...

Страница 17: ...at the sametime for groupcall Every five channelsform one group namely 1 5 6 10 11 15 as one group Tocall a groupin group call press down the firstchannel of routingswitch of thegroup for example 1 6...

Страница 18: ...ompanywill try itsbest to meetyour needs This product canonly be maintainedby our company strained professional personnel The rear coverof the mainframe shall notbe opened withoutour company s authori...

Страница 19: ...e key is pressed Unable to operatenormally after startup The extension cancall the mainframe however it is difficult for themainframe to choose anextension Bus disconnection 1 Extension damaged 2 Conn...

Отзывы: