background image

2. Special nursing setup(take extensions 3, 12 and 30 as an example)

Special nursing extensions have a priority over high level and common extensions in call, and there is a voice 
announcement reporting the extension number and call level. To remove the special nursing setup for an extension, 
just select the routing switch of the channel in the special nursing setup status.

Intensive Care 

Setup

Model:HC

I C Sub Station

Model:HC

After the previous step, press the Function 

key to enter the special nursing setup

3. High level nursing setup(take extensions 6, 10 and 22 as an example)

Urgent Care 

Setup

Model:HC

U Sub Station

Model:HC

After the previous step, press the Function 

key to enter the high level nursing setup

High level nursing extensions have a priority over common extensions in call, and there is a voice announcement 
reporting the extension number and call level. To remove the high level nursing setup for an extension, just select 
the routing switch of the channel in the special nursing setup status.

The mainframe regards all extensions as in common nursing levels by default, and users are not supposed to do 
other settings. When the same extension is configured with multiple nursing levels, the mainframe regards the 
extension as the highest level of setup.

4. Common level setup

12

Press the Function key to enter the minute setup

Model:HC

Set Time

PWR

FUNCTION

MNTR

ALL

PWR

FUNCTION

MNTR

ALL

PWR

FUNCTION

MNTR

ALL

PWR

FUNCTION

MNTR

ALL

PWR

FUNCTION

MNTR

ALL

Model:HC

Set Time

PWR

FUNCTION

MNTR

ALL

Press the     or     key to adjust to 25

Press the     or     key to enter setup

Select the extension routing switches 

of channels 3, 12 and 30

Press the     or     key to enter setup

Select the extension routing switches 

of channels 6, 10 and 22

U Sub Station

06

10

22

I C Sub Station

03

12

30

Содержание HC-30

Страница 1: ...ystem profile Technical specifications System installation System setup Operation instructions Matters for attention Troubleshooting Service commitment Hospital nursing intercom system installation an...

Страница 2: ...e for example alarmsound flashing light and voice announcement XX transfusion completed Three level nursing Threelevels of nursing namely special high and common can be seton the mainframe according t...

Страница 3: ...ht 2 The mainframe haveChinese LCD displaywith menu functionsand operations asa result theoperation is more convenient and simpler and theproduct is ableto display variousstatuses date andtime Only on...

Страница 4: ...to callthe mainframe There is atransfusion alarm interfaceon the extensionthat can cooperatewith the transfusionalarm device When transfusion is completed the extension reportsalarms to themainframe a...

Страница 5: ...talled inthe corridor tofacilitate nursing personnelin the corridorin observing The dot matrixdisplay can displaythe calling extensionnumber and nursinggrade in caseof no call it is ableto display yea...

Страница 6: ...th thewireless receiver When an extensioncalls the wireless transmitter will automaticallytransmit the callingextension number tonursing personnel equipped withthe wireless receiver Generally installe...

Страница 7: ...pecificwiring method pleaserefer to thefollowing Preparation for extensiononline coding Connectone pair ofwhite and blackwires on theextension or the waterproof switch respectivelyonto the two corebus...

Страница 8: ...e 5 Connection betweenthe door lampand extension take theextensions inside thesame ward as an example 1 Connect thered and blackwires of thedoor lamp ontothe red andblack wires ofthe extension accordi...

Страница 9: ...n the mainframe Corridor display 3P 2P 8 Connection betweenmonitoring statistics lineconcentration box monitoringstatistics software computer andmainframe A Insert the power cord into the line concent...

Страница 10: ...tomatically detectextensions The mainframechecks extensions oneby one fromextension 1 theextension is normal andthe indicator lightblinks once ifthere is anyextension wrong orthe channel isnot connect...

Страница 11: ...nursing station Mainframe Level 2management nursing station Power source Line concentration box Corridor display Power source Power source Power source To list of patients To extension outside power s...

Страница 12: ...vel is 01 four panes ofvolume for theday twopanes for volumeat night andfour panes for hands free talkvolume 4 The startupalarm time is00 00 note thisfunction setup isnot activated andthe mainframe fo...

Страница 13: ...and there isa voice announcement reporting the extensionnumber and calllevel To remove thehigh level nursingsetup for anextension just select the routing switchof the channelin the specialnursing set...

Страница 14: ...Call VOL FUNCTION MNTR PWR FUNCTION MNTR ALL FUNCTION MNTR PWR FUNCTION MNTR ALL Volume FUNCTION MNTR Press the or key to enter setup to enter setup Press or key to select the volume Press or key to s...

Страница 15: ...odel HC After the previous step press the Function key to enter the mainframe level setup Tiering Setup Model HC 10 Ward bed setup takeextension 13 setto bed 03of ward 204as an example Sickbed Setup M...

Страница 16: ...vious item press the Function key to enter the forwarding upward duration setup Tier Transfer Setup FUNCTION MNTR ALL Model HC PWR 11 Online coding setup e g code theextension as No 1 extension After...

Страница 17: ...at the sametime for groupcall Every five channelsform one group namely 1 5 6 10 11 15 as one group Tocall a groupin group call press down the firstchannel of routingswitch of thegroup for example 1 6...

Страница 18: ...ompanywill try itsbest to meetyour needs This product canonly be maintainedby our company strained professional personnel The rear coverof the mainframe shall notbe opened withoutour company s authori...

Страница 19: ...e key is pressed Unable to operatenormally after startup The extension cancall the mainframe however it is difficult for themainframe to choose anextension Bus disconnection 1 Extension damaged 2 Conn...