Installation and Commissioning Guide
Advance Outdoor Units
Installation and Commissioning Guide - Advance Split Ducted Outdoor Unit
Doc. No.0525-085 Ver. 2 22xxxx
9
PRELIMINARY DATA ONLY
Ver. 2.04 220704
THIS LABEL TO BE REMOVED ON SIGN-OFF
•
Ensure that spaces around the unit are free from any obstructions for optimum unit performance.
•
Installer to ensure correct size/type that main circuit breaker and cable is installed in unit sub-mains to protect the sub-
mains and unit wiring.
•
Installer to ensure correctly rated residual current device (RCD) is installed as per the latest edition of the AS/NZS 3000
(also known as Australian Wiring Rules).
•
Secure the power cords and control cables that goes in/out the unit. Use the cable ties provided in the control box.
CAUTION
This outdoor unit is designed to match only with an ActronAir indoor unit as specified in the Technical Selection Catalogue.
The unit is supplied with factory charged refrigerant as stated in the Rating Label. The use other material as a refrigerant may
cause explosion and/or personal injury.
Be aware of all the relevant regulations concerning the handling of refrigerant.
For units charged with R-410A
Ensure that R-410A is only charged in liquid form.
For units charged with R-32
R-32 refrigerant (CLASS A2L) is mildly flammable.
Thoroughly read and understand the accompanying R-32 Safety Guide for installation and maintenance instructions.
Installation, service, maintenance, repairs and decommissioning of this unit must be performed by a licensed HVAC technician;
qualified to handle R-32 refrigerant.
Appliance shall be installed, operated and stored in a well ventilated area:
• where the room size corresponds to the room area as specific for operation.
• without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an
operating electric heater).
• away from other potential continuously operating sources that known to cause ignition of R-32 refrigerant.
R-32 refrigerant is odorless if the refrigerant gas comes into contact with fire, it may emit a poisonous gas.
Operation Manual Access
Download from website
Operation manuals can be downloaded through our website shown below.
https://www.actronair.com.au/brochures-manuals/#operating-manuals