Installation and Commissioning Guide
Advance Outdoor Units
Installation and Commissioning Guide - Advance Split Ducted Outdoor Unit
Doc. No.0525-085 Ver. 2 22xxxx
17
PRELIMINARY DATA ONLY
Ver. 2.04 220704
THIS LABEL TO BE REMOVED ON SIGN-OFF
OUTDOOR UNIT
ACCESS PANEL
MOUNTING SCREWS
B
REM OVAL ORDER:
PULL-OUT 20MM
PULL-DOWN TO
REMOVE ACCESS
A
B
A
Remove
ACCESS PANEL
CRA13-17AS-A
T
OD
Unit
Prep
Loosen Bolts
(3-pcs / Comp.)
Shipping Blocks
Outdoor Unit Preparation
1. Remove mounting screws.
2. Remove Access Panel-Electrical as illustrated below.
OUTDOOR UNIT
ACCESS PANEL
MOUNTING SCREWS
B
REM OVAL ORDER:
PULL-OUT 20MM
PULL-DOWN TO
REMOVE ACCESS
A
B
A
Remove
ACCESS PANEL
Loosen Bolts
(3-pcs / Comp.)
Shipping Blocks
3. Remove the Shipping Blocks.
a. Loosen the set bolts that hold the compressors down onto the unit (3 pcs).