SPM-32A ... SPM-36A
5.4 Error limits of the level display
5-11
SPM-34A/-35A
:
Table 5-10
Total error (SPM-34A/-35A)
Error limits
(selective)
1
f=200 Hz to 620 kHz
±
0.7
f=200 Hz to 1.62 MHz
±
0.9
f=50 Hz to 2 MHz
±
1.0
Error limits
(wideband)
2
f=200 Hz to 620 kHz
±
0.8
—
f=200 Hz to 1.62 MHz
±
1.0
—
f=200 Hz to 2 MHz
±
1.1
—
Level range/dBm
1
(75, 135, 150
Ω
)
2
1. RMS measurement
2. Average measurement, display of rms value for sinusoidal signals
+20
-35
-75
(-60)
3
3. Values in brackets apply to 5 Hz bandwidth
Level range/dB, dBm (600
Ω
)
+10
-45
-85
(-70)
3