SPM-32A ... SPM-36A
5.5 Selectivity, bandwidth selectable
5-13
SPM-35A:
Table 5-13
Selectivity (SPM-35A)
Image frequency and IF attenuation
for input levels
≤
0 dBm
SPM-32A/-33A/-34A/-36A
. . . . . . . . . . . . . . > 60 dB
SPM-35A:
at B = 25 Hz to 3.1 kHz
. . . . . . . . . . . . . . . ≥
Š 60 dB
at B = 5 Hz
. . . . . . . . . . . . . . . . . . . . . . ≥
Š 40 dB
3 dB band-
width
(nominal)
Use with VFT
systems
Attenuation at frequency offset
∆
f
≤
0.5 dB
≤
3 dB
≥
17 dB
≥
50 dB
5 Hz
25 Hz
100 Hz
200 Hz
400 Hz
3100 Hz
1
—
—
FM 120
FM 240
FM 480
—
—
—
±
25 Hz
±
60 Hz
±
120 Hz
—
5 Hz
2
±
12 Hz
±
45 Hz
±
100 Hz
±
200 Hz
±
2.7 kHz
2
±
10 Hz
±
50 Hz
±
100 Hz
±
200 Hz
±
400 Hz
—
±
20 Hz
3
±
100 Hz
±
350 Hz
±
700 Hz
±
1 kHz
±
2 kHz
4
1 Effective noise bandwidth 3.1 kHz + 15 %
2 Bandwidth for attenuation < 3 dB
3 Stop-band attenuation
≥
55 dB
4 Stop-band attenuation
≥
55 dB