SPM-32A ... SPM-36A
5.4 Error limits of the level display
5-7
5.4
Error limits of the level display
for Z
in
= Z
out
= Z
0
, after calibration, with display averaging
(AVRG), MAX.HOLD off, battery mode, includes rounding
errors and the signal balance ratio of d.u.t.
≥
20 dB
Note:
The error limits for voltage measurements in dB
can be converted linearly to %, 0.1 dB is approx.
1.2 % (of the measured value).
5.4.1
Intrinsic error and variation with
level
at 10 kHz and (23
±
3)°C (table values in dB)
SPM-32A/33A/36A
:
Table 5-4
Intrinsic error and
variation with level (SPM-32A/-33A/-36A)
Balanced,
all bandwidths
±
0.4
±
0.9 —
Coaxial
B > 100 Hz
B = 100 Hz
±
0.3
±
0.1
±
0.3
±
0.4
±
0.6
B = 25 Hz
±
0.4
Level range/dBm
(75, 135, 150
Ω
)
+ 20
0
0
-70
-80
-90
- 100
Level range/dB, dBm
(600
Ω
)
+10
-80
-90
-100
- 110
Содержание SPM-32A
Страница 1: ...SPM 32A SPM 36A Selective Level Meters Operating Manual BN 4033 00 82 ...
Страница 2: ......
Страница 16: ...2 Safety information SPM 32A SPM 36A 2 4 Notes ...
Страница 118: ...5 10 Ordering information SPM 32A SPM 36A 5 20 ...
Страница 122: ......