SPM-32A ... SPM-36A
4.1 Overview
4-5
MODE
Displays the absolute level in dB or dBm.
Toggle between dB and dBm "dB/dBm"
by entering the key sequence [*], [-].
"REF", using this key sequence you can
alter the reference level
(-120 dB to +20 dB):
•
Enter value using the number keys,
terminate entry with [ENTER]
•
The up / down keys can be used to
increment or decrement "REF".
Shows the difference between the
measured level (dB/dBm) and the stored
reference level "REF".
"ABS--->REF": by entering this key
sequence, the measured absolute level
is stored as the new reference level.
Displays the "reduced level" in dB0 or
dBm0. The absolute level is reduced by
the relative level (dBr).
dB0 = dB - dBr
dBm0 = dBm - dBr
The relative level can be entered by
pressing [*] [dBm0]
"REL (dBr)": allows you to modify the
relative level.
•
Enter value using the number keys
and terminate with [ENTER].
ABS
*
REF
ABS
ABS-REF
ABS-
*
ABS--->REF
REF
dBm0
dBm0
*
REL(dBr)