4.2 Operation and features
4-53
Using a measured level as a reference level
A result is stored as a reference level by entering the
following key sequence:
"!" is displayed in the lower left-hand corner of the display as
an acknowledgment.
Example: Attenuation of a channel filter at 4 kHz
The reference frequency is 1 kHz. The difference between
the levels measured at 1 kHz and 4 kHz is to be determined.
•
Tune the receiver to 1 kHz (reference frequency):
•
Measure the voltage level at 1 kHz
•
Store the measured level as the reference
•
Tune the receiver to 4 kHz
*
ABS
→
REF
ABS-
REF
TUNE
1
ENTER
ABS
*
ABS
→
REF
ABS-
REF
4
ENTER