SERIES IP320 INDUSTRIAL I/O PACK                                     12-BIT HIGH DENSITY ANALOG INPUT BOARD
___________________________________________________________________________________________

- 3 -

INDUSTRIAL I/O PACK INTERFACE FEATURES

 

High density - Single-size, industry standard, IP module
footprint.

 

Local ID - Each IP module has its own 8-bit ID PROM which is
accessed via data transfers in the "ID Read" space.

 

16-bit I/O - Control register Read/Write and A/D
Conversion/Read are performed through 16-bit data transfer
cycles in the IP module I/O space.

 

High Speed - Access times for all data transfer cycles are
described in terms of "wait" states - (typically 0 to 3 wait states
are required for data transfer, see specifications for detailed
information).

 

Wait/Hold State Support - This IP module supports both
“wait” states (generated by the IP module) and “Hold” states
(generated by the carrier board).

SIGNAL INTERFACE PRODUCTS
(See Appendix for more information on compatible products)

This IP module will mate directly to any industry standard IP

carrier board (including Acromag AVME9630/9660 3U/6U non-
intelligent carrier boards).  Consult the documentation of your carrier
board to ensure compatibility with the following interface products
(since all connections to field signals are made through the carrier
board which passes them to the individual IP modules).

Cables:

Model 5025-551-X (Shielded Cable) or Model 5025-550-X (Non-
Shielded Cable):  A Flat 50-pin cable with female connectors at
both ends for connecting AVME9630/9660, or other compatible
carrier boards, to Model 5025-552 termination panels.  The
shielded cable is recommended for optimum performance with
precision analog I/O applications, while the unshielded cable is
recommended for digital I/O.

Termination Panel:

Model 5025-552:  DIN-rail mountable panel provides 50 screw
terminals for universal field I/O termination.  Connects to
Acromag AVME9630/9660, or other compatible carrier boards,
via flat 50-pin ribbon cable (Model 5025-550-X or 5025-551-X).

Transition Module:

Model TRANS-GP:  This module repeats field I/O connections
of IP modules A through D for rear exit from the card cage.  It is
available for use in card cages which provide rear exit for I/O
connections via transition modules (transition modules can only
be used in card cages specifically designed for them).  It is a
double-height (6U), single-slot module with front panel hardware
adhering to the VMEbus mechanical dimensions, except for
shorter printed circuit board depth.  Connects to AVME9630/
9660 boards via a flat 50-pin ribbon cable within the card cage
(cable Model 5025-550-X or 5025-551-X).

INDUSTRIAL I/O PACK SOFTWARE LIBRARY

Acromag provides  an Industrial I/O Pack Software Library

diskette (Model IPSW-LIB-M03, MSDOS format) to simplify
communication with the board.  All functions are written in the “C”
programming language and can be linked to your application.  Refer
to the “README.TXT” file in the root directory and the
“INFO320.TXT” file in the “IP320” subdirectory on the diskette for
more details.

2.0   PREPARATION FOR USE

UNPACKING AND INSPECTION

Upon receipt of this product, Inspect the shipping carton for

evidence of mishandling during transit.   If the shipping carton is
badly damaged or water stained, request that the carrier's agent be
present when the carton is opened.   If the carrier's agent is absent
when the carton is opened and the contents of the carton are
damaged, keep the carton and packing material for the agent's
inspection.

For repairs to a product damaged in shipment, refer to the

Acromag Service Policy to obtain return instructions.   It is
suggested that salvageable shipping cartons and packing material
be saved for future use in the event the product must be shipped.

This board is physically protected with
packing material and electrically
protected with an anti static bag during
shipment.   It is recommended that the
board be visually inspected for evidence
of mishandling prior to applying power.

The board utilizes static sensitive
components and should only be
handled at a static-safe workstation.

CARD CAGE CONSIDERATIONS

Refer to the specifications for

loading and power requirements.   Be
sure that the system power supplies are
able to accommodate the power
requirements of the carrier board, plus
the installed IP modules, within the
voltage tolerances specified.

IMPORTANT: Adequate air circulation must be provided to prevent
a temperature rise above the maximum operating temperature.

The dense packing of the IP modules to the carrier board

restricts air flow within the card cage and is cause for concern.
Adequate air circulation must be provided to prevent a temperature
rise above the maximum operating temperature and to prolong the
life of the electronics.   If the installation is in an industrial
environment and the board is exposed to environmental air, careful
consideration should be given to air-filtering.

BOARD CONFIGURATION

The board may be configured differently, depending on the

application.  All possible jumper settings will be discussed in the
following sections.  The jumper locations are shown in Drawing
4501-433.

Power should be removed from the board when configuring

hardware jumpers, installing IP's, cables, termination panels and
field wiring.  Refer to Drawing 4501-434 and IP documentation for IP
configuration and assembly instructions.

Содержание IP320 Series

Страница 1: ...Board USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1994 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8500 484 F00J005 retired ...

Страница 2: ... MECHANICAL ASSEMBLY 15 4501 435 ANALOG INPUT CONNECTION DIAGRAM 16 4501 436 BLOCK DIAGRAM 16 4501 462 CABLE 5025 550 NON SHIELDED 17 4501 463 CABLE 5025 551 SHIELDED 17 4501 464 TERMINATION PANEL 5025 552 18 4501 465 TRANSITION MODULE TRANS GP 18 IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider the possible adverse effects of power wiring component sensor or software ...

Страница 3: ...able Model 5025 550 X or 5025 551 X INDUSTRIAL I O PACK SOFTWARE LIBRARY Acromag provides an Industrial I O Pack Software Library diskette Model IPSW LIB M03 MSDOS format to simplify communication with the board All functions are written in the C programming language and can be linked to your application Refer to the README TXT file in the root directory and the INFO320 TXT file in the IP320 subdi...

Страница 4: ...ol register is software configurable There are no hardware jumpers associated with it Control register bits are undefined at reset and must be programmed to the desired gain acquisition mode and channel configuration before starting ADC analog input acquisition refer to Section 3 for details Analog Input Data Format The analog input data will appear as Unipolar Straight Binary USB for unipolar inp...

Страница 5: ...ame location e g printed circuit board The channel density doubles when using single ended inputs and this a powerful incentive for their use However caution must be exercised since the single sense lead references all channels to the same common which will induce noise and offset if they are different The IP320 is non isolated since there is electrical continuity between the logic and field I O g...

Страница 6: ... not respond to addresses that are Not Used The function of each register noted in Table 3 1 will be discussed in the following sections IP Identification PROM Read Only 32 odd byte addresses Each IP module contains an identification ID PROM that resides in the ID space per the IP module specification This area of memory contains 32 bytes of information at most Both fixed and variable information ...

Страница 7: ... per the following table Note that the SEL HIGH bit and MODE bits are also shown to completely define the channel selection When MODE 1 MODE 0 are both 0 differential channels 0 19 and calibration voltages 0 3 may be selected when MODE 1 is 0 and MODE 0 is 1 single ended channels 0 19 may be selected when MODE 1 is 1 and MODE 0 is 0 single ended channels 20 39 may be selected when both MODE 1 MODE...

Страница 8: ...ates until it can deliver the data 7 Repeat steps 3 6 as required to acquire additional analog input samples Note that the input settling delay does not have to be inserted since writing to the control register to configure for the next acquisition immediately after initiating the previous conversion will allow the input to adequately settle before the next conversion is started The overlapping of...

Страница 9: ...ur voltages and the analog ground reference are used to determine the endpoints of a straight line which defines the analog input characteristic The calibration voltages are precisely adjusted at the factory to provide optimum performance as detailed in the following table Calibration Signal Ideal Value Volts Maximum Tolerance 25oC Volts Maximum Temperature Drift ppm oC Auto Zero 0 0000 0 0002 0 C...

Страница 10: ...ts are set to zero 2 Delay to allow for input settling 3 Execute ADC Convert Command Base 10H 4 Execute Read ADC Data Command Base 20H Note that the 12 bit data is left justified within the 16 bit word 5 Repeat steps 3 and 4 several times e g 16 and take the average of the ADC results Save this number as CountCALLO 6 To prepare to measure CountCALHI write to the Control Register Base 00H to setup ...

Страница 11: ...y possible for each range It is the sum of error components due to ADC quantization of the low and high calibration signals PGA and ADC linearity error and the absolute errors of the recommended calibration voltages at 25oC Typical accuracies are significantly better Table 3 6 Maximum Overall Calibrated Error 25 C Input Range Volts PGA Gain ADC Range Volts Max Error LSB Span 5 to 5 1 5 to 5 1 8 0 ...

Страница 12: ...nput circuitry The ID PROM control register and ADC data are all accessed through the 16 bit data bus interface to the carrier board 5 0 SERVICE AND REPAIR SERVICE AND REPAIR ASSISTANCE Surface Mounted Technology SMT boards are generally difficult to repair It is highly recommended that a non functioning board be returned to Acromag for repair The board can be damaged unless special SMT repair and...

Страница 13: ...e programmable gain to determine the actual input range Input signal ranges may actually fall short of reaching the specified endpoints due to hardware limitations For example if an input may reach zero volts or less a bipolar input range should be selected 3 These ranges can only be achieved with 15 Volt external power supplies The input ranges will be clipped if 12 Volt supplies are used typical...

Страница 14: ...n assignments Refer to the IP module manual for correct wiring connections to the termination panel Schematic and Physical Attributes See Drawing 4501 464 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to AVME9630 9660 P1 50 pin male header with strain relief ejectors Use Acromag 5025 550 x or 5025 551 x cable to connect panel to VME board Keep cable...

Страница 15: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 15 ...

Страница 16: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 16 ...

Страница 17: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 17 ...

Страница 18: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 18 ...

Отзывы: