SERIES IP320 INDUSTRIAL I/O PACK                                     12-BIT HIGH DENSITY ANALOG INPUT BOARD
___________________________________________________________________________________________

- 14 -

APPENDIX

CABLE:  MODEL 5025-550-x (Non-Shielded)
                MODEL 5025-551-x (Shielded)

Type:  Flat Ribbon Cable, 50-wires (female connectors at both

ends).  The ‘-x’ suffix designates the length in feet (12 feet
maximum).  Choose shielded or unshielded cable according to
model number.  The unshielded cable is recommended for
digital I/O, while the shielded cable is recommended for
optimum performance with precision analog I/O applications.

Application:  Used to connect Model 5025-552 termination panel to

the AVME9630/9660 non-intelligent carrier board P3-P6
connectors (Both have 50-pin connectors).

Length:  Last field of part number designates length in feet (user-

specified, 12 feet maximum).  It is recommended that this length
be kept to a minimum to reduce noise and power loss.

Cable:  50-wire flat ribbon cable, 28 gage.  Non-Shielded cable

model uses Acromag Part 2002-211 (3M Type C3365/50 or
equivalent).  Shielded cable model uses Acromag Part 2002-261
(3M Type 3476/50 or equivalent).

Headers (Both Ends):  50-pin female header with strain relief.

Header - Acromag Part 1004-512 (3M Type 3425-6600 or
equivalent).  Strain Relief - Acromag Part 1004-534 (3M Type
3448-3050 or equivalent).

Keying:  Headers at both ends have polarizing key to prevent

improper installation.

Schematic and Physical Attributes:  For Non-Shielded cable model,

see Drawing 4501-462.  For Shielded cable model, see Drawing
4501-463.

Shipping Weight:  1.0 pound (0.5Kg), packed.

TERMINATION PANEL:  MODEL 5025-552

Type:  Termination Panel For AVME9630/9660 Boards
Application:  To connect field I/O signals to the Industrial I/O Pack

(IP).  Termination Panel:  Acromag Part 4001-040  (Phoenix
Contact Type FLKM 50).  The 5025-552 termination panel
facilitates the connection of up to 50 field I/O signals and
connects to the AVME9630/9660 3U/6U non-intelligent carrier
boards (P3-P6 connectors only) via a flat ribbon cable (Model
5025-550-x or 5025-551-x).  The P3-P6 connectors on the
carrier board connect the field I/O signals to the P2 connector
on each of the Industrial I/O Pack modules.  Field signals are
accessed via screw terminal strips.  The terminal strip markings
on the termination panel (1-50) correspond to P2 (pins 1-50) on
the Industrial I/O Pack (IP).  Each Industrial I/O Pack (IP) has
its own unique P2 pin assignments.  Refer to the IP module
manual for correct wiring connections to the termination panel.

Schematic and Physical Attributes:  See Drawing 4501-464.
Field Wiring:  50-position terminal blocks with screw clamps.  Wire

range 12 to 26 AWG.

Connections to AVME9630/9660:  P1, 50-pin male header with

strain relief ejectors.  Use Acromag 5025-550-x or 5025-551-x
cable to connect panel to VME board.   Keep cable as short as
possible to reduce noise and power loss.

Mounting:  Termination panel is snapped on the DIN mounting rail.
Printed Circuit Board:  Military grade FR-4 epoxy glass circuit board,

0.063 inches thick.

Operating Temperature:  -40

°

C to +100

°

C.

Storage Temperature:     -40

°

C to +100

°

C.

Shipping Weight:  1.25 pounds (0.6kg) packed.

TRANSITION MODULE: MODEL TRANS-GP

Type:  Transition module for AVME9630/9660 boards.
Application:  To repeat field I/O signals of IP modules A through D

for rear exit from VME card cages.  This module is available for
use in card cages which provide rear exit for I/O connections via
transition modules (transition modules can only be used in card
cages specifically designed for them).  It is a double-height
(6U), single-slot module with front panel hardware adhering to
the VMEbus mechanical dimensions, except for shorter printed
circuit board depth.  Connects to Acromag termination panel
5025-552 from the rear of the card cage, and to
AVME9630/9660 boards within card cage, via flat 50-pin ribbon
cable (cable Model 5025-550-X or 5025-551-X).

Schematic and Physical Attributes:  See Drawing 4501-465.
Field Wiring:  50-pin header (male) connectors (3M 3433-D303 or

equivalent) employing long ejector latches and 30 micron gold in
the mating area (per MIL-G-45204, Type II, Grade C).
Connects to Acromag termination panel 5025-552 from the rear
of the card cage, or to AVME9630/9660 boards within card
cage, via flat 50-pin ribbon cable (cable Model 5025-550-X or
5025-551-X).

Connections to AVME9630/9660: 50-pin header (male) connectors

(3M 3433-1302 or equivalent) employing long ejector latches
and 30 micron gold in the mating area (per MIL-G-45204, Type
II, Grade C).  Connects to AVME9630/9660 boards within the
card cage via flat 50-pin ribbon cable (cable Model 5025-550-X
or 5025-551-X).  Transition module is inserted into a 6U-size,
single-width slot at the rear of the VMEbus card cage.

Mounting:  Transition module is inserted into a 6U-size, single-width

slot at the rear of the VMEbus card cage.

Printed Circuit Board:  Military grade FR-4 epoxy glass circuit board,

0.063 inches thick.

Operating Temperature:  -40 to +85

°

C.

Storage Temperature:  -55

°

C to +105

°

C.

Shipping Weight:  1.25 pounds (0.6Kg) packed.

Содержание IP320 Series

Страница 1: ...Board USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1994 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8500 484 F00J005 retired ...

Страница 2: ... MECHANICAL ASSEMBLY 15 4501 435 ANALOG INPUT CONNECTION DIAGRAM 16 4501 436 BLOCK DIAGRAM 16 4501 462 CABLE 5025 550 NON SHIELDED 17 4501 463 CABLE 5025 551 SHIELDED 17 4501 464 TERMINATION PANEL 5025 552 18 4501 465 TRANSITION MODULE TRANS GP 18 IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider the possible adverse effects of power wiring component sensor or software ...

Страница 3: ...able Model 5025 550 X or 5025 551 X INDUSTRIAL I O PACK SOFTWARE LIBRARY Acromag provides an Industrial I O Pack Software Library diskette Model IPSW LIB M03 MSDOS format to simplify communication with the board All functions are written in the C programming language and can be linked to your application Refer to the README TXT file in the root directory and the INFO320 TXT file in the IP320 subdi...

Страница 4: ...ol register is software configurable There are no hardware jumpers associated with it Control register bits are undefined at reset and must be programmed to the desired gain acquisition mode and channel configuration before starting ADC analog input acquisition refer to Section 3 for details Analog Input Data Format The analog input data will appear as Unipolar Straight Binary USB for unipolar inp...

Страница 5: ...ame location e g printed circuit board The channel density doubles when using single ended inputs and this a powerful incentive for their use However caution must be exercised since the single sense lead references all channels to the same common which will induce noise and offset if they are different The IP320 is non isolated since there is electrical continuity between the logic and field I O g...

Страница 6: ... not respond to addresses that are Not Used The function of each register noted in Table 3 1 will be discussed in the following sections IP Identification PROM Read Only 32 odd byte addresses Each IP module contains an identification ID PROM that resides in the ID space per the IP module specification This area of memory contains 32 bytes of information at most Both fixed and variable information ...

Страница 7: ... per the following table Note that the SEL HIGH bit and MODE bits are also shown to completely define the channel selection When MODE 1 MODE 0 are both 0 differential channels 0 19 and calibration voltages 0 3 may be selected when MODE 1 is 0 and MODE 0 is 1 single ended channels 0 19 may be selected when MODE 1 is 1 and MODE 0 is 0 single ended channels 20 39 may be selected when both MODE 1 MODE...

Страница 8: ...ates until it can deliver the data 7 Repeat steps 3 6 as required to acquire additional analog input samples Note that the input settling delay does not have to be inserted since writing to the control register to configure for the next acquisition immediately after initiating the previous conversion will allow the input to adequately settle before the next conversion is started The overlapping of...

Страница 9: ...ur voltages and the analog ground reference are used to determine the endpoints of a straight line which defines the analog input characteristic The calibration voltages are precisely adjusted at the factory to provide optimum performance as detailed in the following table Calibration Signal Ideal Value Volts Maximum Tolerance 25oC Volts Maximum Temperature Drift ppm oC Auto Zero 0 0000 0 0002 0 C...

Страница 10: ...ts are set to zero 2 Delay to allow for input settling 3 Execute ADC Convert Command Base 10H 4 Execute Read ADC Data Command Base 20H Note that the 12 bit data is left justified within the 16 bit word 5 Repeat steps 3 and 4 several times e g 16 and take the average of the ADC results Save this number as CountCALLO 6 To prepare to measure CountCALHI write to the Control Register Base 00H to setup ...

Страница 11: ...y possible for each range It is the sum of error components due to ADC quantization of the low and high calibration signals PGA and ADC linearity error and the absolute errors of the recommended calibration voltages at 25oC Typical accuracies are significantly better Table 3 6 Maximum Overall Calibrated Error 25 C Input Range Volts PGA Gain ADC Range Volts Max Error LSB Span 5 to 5 1 5 to 5 1 8 0 ...

Страница 12: ...nput circuitry The ID PROM control register and ADC data are all accessed through the 16 bit data bus interface to the carrier board 5 0 SERVICE AND REPAIR SERVICE AND REPAIR ASSISTANCE Surface Mounted Technology SMT boards are generally difficult to repair It is highly recommended that a non functioning board be returned to Acromag for repair The board can be damaged unless special SMT repair and...

Страница 13: ...e programmable gain to determine the actual input range Input signal ranges may actually fall short of reaching the specified endpoints due to hardware limitations For example if an input may reach zero volts or less a bipolar input range should be selected 3 These ranges can only be achieved with 15 Volt external power supplies The input ranges will be clipped if 12 Volt supplies are used typical...

Страница 14: ...n assignments Refer to the IP module manual for correct wiring connections to the termination panel Schematic and Physical Attributes See Drawing 4501 464 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to AVME9630 9660 P1 50 pin male header with strain relief ejectors Use Acromag 5025 550 x or 5025 551 x cable to connect panel to VME board Keep cable...

Страница 15: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 15 ...

Страница 16: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 16 ...

Страница 17: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 17 ...

Страница 18: ...SERIES IP320 INDUSTRIAL I O PACK 12 BIT HIGH DENSITY ANALOG INPUT BOARD ___________________________________________________________________________________________ 18 ...

Отзывы: