AcroPack Series AP560
CAN Bus Interface Module
- 43 -
000 - Normal Mode. Normal CAN operation.
001 - Loopback Mode. The transceiver digital input is fed
back to the receiver without disturbing the bus. This
mode can be used for test purposes, allowing the
HI-3111 to receive its own messages.
010 - Monitor Mode. The HI-3111 can be set up to monitor
bus activity without transmitting to the bus (no ACK
bits or error frames are sent in this mode). Receive
filters can be programmed in Initialization Mode to
buffer selected messages.
011 - Sleep Mode. The HI-3111 can be placed in a low
power sleep mode if there is no bus activity and the
transmit FIFO is empty. Sleep mode is exited by
selecting an alternative mode of operation, or
automatic wake up following bus activity can be
enabled by setting the WAKEUP bit. The device will
wake up in Monitor mode.
1xx - Initialization Mode. The device
must
be in this mode
for bit timing and filter set-up. This is the default
following reset. The host exits initialization mode by
selecting an alternative mode of operation.