AcroPack Series AP560
CAN Bus Interface Module
- 9 -
For repairs to a product damaged in shipment, refer to the Acromag Service
Policy to obtain return instructions. It is suggested that salvageable shipping
cartons and packing material be saved for future use in the event the product
must be shipped.
This board is physically protected with packing material and electrically
protected with an anti-static bag during shipment. However, it is
recommended that the board be visually inspected for evidence of
mishandling prior to applying power.
The board utilizes static sensitive components and should only be handled at
a static-safe workstation.
Installation Considerations
Refer to the specifications for loading and power requirements. Be sure that
the system power supplies can accommodate the power requirements of the
carrier board, plus the installed AcroPack modules, within the voltage
tolerances specified.
IMPORTANT: Adequate air circulation must be provided to prevent a temperature rise above the maximum
operating temperature.
The dense packing of the AcroPack module to the carrier/CPU board restricts
air flow within the card cage and is cause for concern. Adequate air circulation
must be provided to prevent a temperature rise above the maximum
operating temperature and to prolong the life of the electronics. If the
installation is in an industrial environment and the board is exposed to
environmental air, careful consideration should be given to air-filtering.
In a conduction cooled assembly, adequate thermal conduction must be
provided to prevent a temperature rise above the maximum operating
temperature.
CONNECTORS
Field I/O Connector P2
A field I/O interface connector provides a mating interface between the AP
modules and the carrier board. The 100 pin ST5-50-1.50-L-D-P-TR Samtec
connector is used on the AcroPack card as board to board interconnect. This
connector will mate with the 100 pin SS5-50-3.00-L-D-K-TR Samtec connector
on the carrier. The stack height is 4.5mm.
Pin assignments are unique to each AP model. Table 1 lists signal pin
assignments for the module field I/O connector. Pins are left unconnected to
meet the minimum creepage distance required for 60 Volt isolation. Front
panel connector P2 pin assignments are shown in Table 1.
Содержание AcroPack AP560
Страница 28: ...AcroPack Series AP560 CAN Bus Interface Module 28 Figure 2 Standard Data Frame...
Страница 30: ...AcroPack Series AP560 CAN Bus Interface Module 30 Figure 3 Extended Data Frame...
Страница 32: ...AcroPack Series AP560 CAN Bus Interface Module 32 Figure 4 Remote Frame...
Страница 34: ...AcroPack Series AP560 CAN Bus Interface Module 34 Figure 5 Error Frame...