Acromag ACPC8625 Series Скачать руководство пользователя страница 18

______________________________________________________________________

TRANSITION MODULE:  MODEL TRANS-C200

______________________________________________________________________

Type:  Transition Module For ACPC8625 Boards

The TRANS-C200 transition module plugs into the rear backplane directly behind the carrier board.  The field I/O
connections are made through the backplane to J4 and J5 connectors of the carrier board and then routed to four
SCSI-2 connectors on the transition module (marked IP module slots “A through D”) for rear exit from the card
cage.  It is available for use in CompactPCI bus card cages which provide rear exit for I/O connections via
transition modules (transition modules can only be used in card cages specifically designed for them).  It is a
double-height (6U), single-slot module with front panel hardware adhering to the CompactPCI mechanical
dimensions and IEEE Standard (1101.11-1998), with a printed circuit board depth of 80mm, which is a standard
transition module depth.  The transition module connects to Acromag Termination Panel (Model 5025-552) using
SCSI-2 to Flat Ribbon Cable, Shielded (Model 5028-187) to the rear of the card cage, and to ACPC8625 boards
within the card cage

.

Application........................................................... To repeat field I/O signals of IP modules A through D for rear 

exit from CompactPCI card cages.

Schematic and Physical Attributes...................... See Drawing 4501-791 (Over).
Electrical Specifications....................................... 30 VAC per UL and CSA (SCSI-2 connector spec.’s).

1 Amp maximum at 50% energized (SCSI-2 connector spec.’s).

Field Wiring.......................................................... Four SCSI-2, 50-pin female connectors (AMP 787082-5 or

equivalent) employing latch blocks and 30 micron gold in the
mating area (per MIL-G-45204, Type II, Grade C).  Connects to
Acromag termination panel 5025-552 from the rear of the card
cage via round shielded cable (Model 5028-187).

Connections to ACPC8625...................................Connections are made though the PC board connectors J4

(110 signals, female right angle with upper ground shield-keyed) 
and J5 (110 signals, female right angle with upper ground shield).
The transition module plugs directly behind the ACPC8625 board
into the CompactPCI bus backplane within the card cage system.

Mounting.............................................................. Transition module is inserted into a 6U-size, 80 mm width slot at

the rear of the CompactPCI bus card cage.
(Directly behind ACPC8625 board)

Printed Circuit Board........................................... Eight-layer, military-grade FR-4 epoxy glass circuit board, 0.063

inches thick.

Operating Temperature....................................... -40

°

C to +85

°

C.

Storage Temperature.......................................... -40

°

C to +85

°

C.

Shipping Weight.................................................. 1.25 pounds (0.6Kg) packed.

ACROMAG INCORPORATED
30765 South Wixom Road
P.O. BOX 437
Wixom, MI 48393-7037 U.S.A.
Tel:  (248) 624-1541
Fax: (248) 624-9234

Copyright 1999 Acromag, Inc., Printed in USA
Data and specifications subject to change without notice

8500-623-B00D012

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание ACPC8625 Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...ED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1999 Acromag Inc Printed in the USA Data and specifications are subject to change without no...

Страница 3: ...5025 552 13 CompactPCI TRANSITION MODULE MODEL TRANS C200 13 DRAWINGS Page 4501 788 ACPC8625 IP LOCATIONS 14 4501 789 IP MECHANICAL ASSEMBLY DRAWING 14 4501 790 ACPC8625 BLOCK DIAGRAM 15 4501 758 CABL...

Страница 4: ...sitive self locking mechanism so they cannot be unlocked accidentally These handles are fully IEEE 1101 10 compliant and are needed to give leverage to install and remove the board EMC Front Panel The...

Страница 5: ...the IP modules to the carrier board alone results in elevated IP module and carrier board temperatures and the restricted air flow within the chassis aggravates this problem Adequate air circulation...

Страница 6: ...2 6 MEMSEL 31 D03 7 DMAReq1 32 D04 8 IntSel 33 D05 9 DMAck0 34 D06 10 IOSEL 35 D07 11 RESERVED 36 D08 12 A1 37 D09 13 DMAEnd 38 D10 14 A2 39 D11 15 ERROR 40 D12 16 A3 41 D13 17 INTReq0 42 D14 18 A4 43...

Страница 7: ...ponent side J5 is used to route IP Modules C D field signals from the carrier to the backplane TABLE 2 4 CompactPCI I O Signals J5 CONNECTIONS Pin Row A Row B Row C Row D Row E Row F 1 3 3V 3 3V 3 3V...

Страница 8: ...memory address range assigned The configuration registers are also used to indicate that the CompactPCI carrier requires an interrupt request line The system software then programs the configuration...

Страница 9: ...Address Hex High Byte D15 D08 Low Byte D07 D00 Base Address Hex 0141 017F Not Used Not Used 0140 017E 0181 01FF IP A I O Space IP A I O Space 0180 01FE 0201 027F IP B I O Space IP B I O Space 0200 02...

Страница 10: ...ace is read to respond to an interrupt request via the IP Module s INTREQ1 signal An access to an interrupt select space results in the IP module serving up an interrupt vector In addition access to t...

Страница 11: ...pactPCI bus interface is also used to communicate with and control external devices that are connected to an IP module s field I O signals assuming an IP module is present on the carrier board The Com...

Страница 12: ...oning board be returned to Acromag for repair The board can be damaged unless special SMT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks the perf...

Страница 13: ...Upon power up the system auto configuration process plug play maps the carrier s base address for a 1K byte block of memory into the PCI bus 32 bit Memory Space INDUSTRIAL I O PACK COMPLIANCE Specific...

Страница 14: ...and Physical Attributes See Drawing 4501 464 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to TRANS C200 Transition Module P1 50 pin male header with s...

Страница 15: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 14 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 16: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 15 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 17: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 16 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 18: ...card cages Schematic and Physical Attributes See Drawing 4501 791 Over Electrical Specifications 30 VAC per UL and CSA SCSI 2 connector spec s 1 Amp maximum at 50 energized SCSI 2 connector spec s Fi...

Страница 19: ...2 4501 791B Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 20: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: