Acromag ACPC8625 Series Скачать руководство пользователя страница 14

INDUSTRIAL I/O PACK SERIES ACPC8625                                               CompactPCI BUS CARRIER BOARD
___________________________________________________________________________________________

- 13 -

Radiated Emissions..................... Meets or exceeds European
                                                    Norm EN50081-1 for class A
                                                     equipment.

APPENDIX

CABLE:  MODEL 5028-187 (SCSI-2 to Flat Ribbon, Shielded)

Type:  Round shielded cable, 50-wires (SCSI-2 male connector at

one end and a flat female ribbon connector at the other end).
The cable length is 2 meters (6.56 feet).  This shielded cable is
recommended for all I/O applications (both digital I/O and
precision analog I/O).

Application:  Used to connect Model 5025-552 termination panel to

the TRANS-C200 Transition Module.  The transition module
then  connects to all four IP module slots to the rear of the
ACPC8625  (Slots A-D).

Length:  Standard lenght is 2 meters (6.56 feet).  Consult factory for

other length.  It is recommended that this length be kept to a
minimum to reduce noise and power loss.

Cable:  50 conductors, 28 AWG on 0.050 inch centers (permits

mass termination for IDC connectors), foil/braided shield inside
a PVC jacket.

Connectors:  (One End):  SCSI-2, 50-pin male connector with

backshell and spring latch hardware.  (Other End):  IDC, 50-pin
female connector with strain relief.

Keying:  The SCSI-2 connector has a “D Shell” and the IDC

connector has a polarizing key to prevent improper installation.

Schematic and Physical Attributes:  See Drawing 4501-758.
Electrical Specifications:  30 VAC per UL and CSA (SCSI-2

connector spec.’s).  1 Amp maximum at 50% energized
(SCSI-2 connector spec.’s).

Operating Temperature: -20

°

C to +80

°

C.

Storage Temperature:  -40

°

C to +85

°

C.

Shipping Weight:  1.0 pound (0.5Kg), packed.

TERMINATION PANEL:  MODEL 5025-552

Type:  Termination Panel For Carrier Boards
Application:  To connect field I/O signals to the Industrial I/O Pack

(IP).  Termination Panel:  Acromag Part 4001-040  (Phoenix
Contact Type FLKM 50).  The 5025-552 termination panel
facilitates the connection of up to 50 field I/O signals and
connects to the TRANS-C200 transition module via a cable
(Model 5028-187). Field signals are accessed via screw terminal
strips.  The terminal strip markings on the termination panel (1-
50) correspond to P2 (pins 1-50) on the Industrial I/O Pack (IP).
Each Industrial I/O Pack (IP) has its own unique P2 pin
assignments.  Refer to the IP module manual for correct wiring
connections to the termination panel.

Schematic and Physical Attributes:  See Drawing 4501-464.
Field Wiring:  50-position terminal blocks with screw clamps.  Wire

range 12 to 26 AWG.

Connections to TRANS-C200 Transition Module:  P1, 50-pin male

header with strain relief ejectors.  Use Acromag 5028-187 cable
to connect panel to TRANS-C200 transition module.   Keep
cable as short as possible to reduce noise and power loss.

Mounting:  Termination panel is snapped on the DIN mounting rail.
Printed Circuit Board:  Military grade FR-4 epoxy glass circuit board,

0.063 inches thick.

Operating Temperature:  -40

°

C to +100

°

C.

Storage Temperature:  -40

°

C to +100

°

C.

Shipping Weight:  1.25 pounds (0.6kg) packed.

CompactPCI TRANSITION MODULE: MODEL TRANS-C200

Type:  Transition module for ACPC8625 board.
Application:  To repeat field I/O signals of IP modules A through D

for rear exit from CompactPCI card cages.  This module is
available for use in card cages which provide rear exit for I/O
connections via 80 mm wide transition modules (transition
modules can only be used in card cages specifically designed
for them). It is a double-height (6U), single-slot module with front
panel hardware adhering to the CompactPCI bus mechanical
dimensions and IEEE Standard (1101.11-1998), for 80 mm
depth.  Connects to Acromag termination panel 5025-552 from
the rear of the card cage, and to ACPC8625 boards within card
cage, via connectors P4 and P5.

Schematic and Physical Attributes:  See Drawing 4501-791.
Electrical Specifications:  30 VAC per UL and CSA (SCSI-2

connector spec.’s).  1 Amp maximum at 50% energized
(SCSI-2 connector spec.’s).

Field Wiring:  Four SCSI-2, 50-pin female connectors (AMP

787082-5 or equivalent) employing latch blocks and 30 micron
gold in the mating area (per MIL-G-45204, Type II, Grade C).
Connects to Acromag termination panel 5025-552 from the rear
of the card cage via round shielded cable (Model 5028-187).

Connections to ACPC8625: Connections are made though the PC

board connectors P4 and P5 (right-angle female connector, 110
contacts with upper shield.  The transition module plugs directly
behind the ACPC8625 board into the CompactPCI bus
backplane within the card cage system.

Mounting:  Transition module is inserted into a 6U-size, 80 mm

width slot at the rear of the CompactPCI bus card cage.
(Directly behind ACPC8625 board)

Printed Circuit Board:  Eight-layer, military-grade FR-4 epoxy glass

circuit board, 0.063 inches thick.

Operating Temperature: -40

°

C to +85

°

C.

Storage Temperature:  -40

°

C to +85

°

C.

Shipping Weight:  1.25 pounds (0.6Kg) packed.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание ACPC8625 Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...ED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1999 Acromag Inc Printed in the USA Data and specifications are subject to change without no...

Страница 3: ...5025 552 13 CompactPCI TRANSITION MODULE MODEL TRANS C200 13 DRAWINGS Page 4501 788 ACPC8625 IP LOCATIONS 14 4501 789 IP MECHANICAL ASSEMBLY DRAWING 14 4501 790 ACPC8625 BLOCK DIAGRAM 15 4501 758 CABL...

Страница 4: ...sitive self locking mechanism so they cannot be unlocked accidentally These handles are fully IEEE 1101 10 compliant and are needed to give leverage to install and remove the board EMC Front Panel The...

Страница 5: ...the IP modules to the carrier board alone results in elevated IP module and carrier board temperatures and the restricted air flow within the chassis aggravates this problem Adequate air circulation...

Страница 6: ...2 6 MEMSEL 31 D03 7 DMAReq1 32 D04 8 IntSel 33 D05 9 DMAck0 34 D06 10 IOSEL 35 D07 11 RESERVED 36 D08 12 A1 37 D09 13 DMAEnd 38 D10 14 A2 39 D11 15 ERROR 40 D12 16 A3 41 D13 17 INTReq0 42 D14 18 A4 43...

Страница 7: ...ponent side J5 is used to route IP Modules C D field signals from the carrier to the backplane TABLE 2 4 CompactPCI I O Signals J5 CONNECTIONS Pin Row A Row B Row C Row D Row E Row F 1 3 3V 3 3V 3 3V...

Страница 8: ...memory address range assigned The configuration registers are also used to indicate that the CompactPCI carrier requires an interrupt request line The system software then programs the configuration...

Страница 9: ...Address Hex High Byte D15 D08 Low Byte D07 D00 Base Address Hex 0141 017F Not Used Not Used 0140 017E 0181 01FF IP A I O Space IP A I O Space 0180 01FE 0201 027F IP B I O Space IP B I O Space 0200 02...

Страница 10: ...ace is read to respond to an interrupt request via the IP Module s INTREQ1 signal An access to an interrupt select space results in the IP module serving up an interrupt vector In addition access to t...

Страница 11: ...pactPCI bus interface is also used to communicate with and control external devices that are connected to an IP module s field I O signals assuming an IP module is present on the carrier board The Com...

Страница 12: ...oning board be returned to Acromag for repair The board can be damaged unless special SMT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks the perf...

Страница 13: ...Upon power up the system auto configuration process plug play maps the carrier s base address for a 1K byte block of memory into the PCI bus 32 bit Memory Space INDUSTRIAL I O PACK COMPLIANCE Specific...

Страница 14: ...and Physical Attributes See Drawing 4501 464 Field Wiring 50 position terminal blocks with screw clamps Wire range 12 to 26 AWG Connections to TRANS C200 Transition Module P1 50 pin male header with s...

Страница 15: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 14 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 16: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 15 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 17: ...ACPC8625 CompactPCI BUS CARRIER BOARD ___________________________________________________________________________________________ 16 Artisan Technology Group Quality Instrumentation Guaranteed 888 88...

Страница 18: ...card cages Schematic and Physical Attributes See Drawing 4501 791 Over Electrical Specifications 30 VAC per UL and CSA SCSI 2 connector spec s 1 Amp maximum at 50 energized SCSI 2 connector spec s Fi...

Страница 19: ...2 4501 791B Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 20: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: