DC Inverter
X-Series
for R410A Unitary Split Air Conditioner
5
2 Product Introduction
2.1 Operating Range
—
Cooling
Outdoor temperature
39.2
°
F(4°C)~118.4
°
F (48°C)
2.2 Standard Accessories
Outdoor unit accessories
No.
Name
Appearance
Q'ty
Usage
1
Drain plug
3
To plug the unused drain
hole
2.3 Optional Accessories
Outdoor unit accessories
No.
Name
Appearance
Q'ty
Usage
1
Throw-over
pipe
1
Connect the unit
with the liquid
pipe
2
Throw-over
pipe
1
Connect the unit
with the gas
pipe
3 Installation
3.1 Installation Preparation
3.1.1 Selection of Installation Location
①
. The unit must be installed where strong enough to withstand the weight of the unit
and fixed securely, otherwise the unit would topple or fall off.
②
. Install the air conditioner at a place where the inclination is less than 5°.
③
. Do not install the unit at a place with direct sunlight.
④
. Do not install where there is the danger of combustible gas leakage.
⑤
. Do not install the unit at a place with leakage of inflammable gas.