DC Inverter
X-Series
for R410A Unitary Split Air Conditioner
17
(2) If the outdoor unit is above the indoor unit, arrange the pipeline according to the
following diagram.
1) Wind the insulating tape from bottom to top.
2) The whole pipeline should be wound together to avoid water returning to
the room.
3) Use saddles to fix the whole pipeline onto the wall.
3.3 Electrical Installation
3.3.1 Requirement and Notice on Electrical Installation
The electrical installation for the air conditioner should observe the following
requirements:
①
. The electrical installation must be conducted by professionals in compliance with
local laws and regulations and the instructions in this manual. Never extend the
power cords. The electric circuit must be equipped with a circuit breaker and air
switch both with sufficient capacity.
②
. The unit’s operating power must be within the nominal range stated in the
instruction manual. Use a specialized power circuit for the air conditioner. Do not
draw power from another power circuit.
③
. The air conditioner circuit should be at least 1.5m away from any inflammable
surface.
④
. The external power cords, the thermostat wires and outdoor unit must be
effectively fixed.
⑤
. The external power cords, the thermostat wires and outdoor unit can’t directly
contact any hot objects. For example: they must not contact chimney pipes, warm