63
3
rd
digit
4
th
digit
2.The value is factory set value of models with analog operator.
Function
Pn-
Name
Description
Initial
Setting
User
Set
Values
Ref.
Par
02 Maximum
Output
Frequency
Setting unit:0.1 Hz
Setting range:50.0 to 400.0Hz
60.0Hz
03 Maximum
Voltage
Setting unit:0.1Hz
Setting range:0.1 to 255.0V
220V
(Note 1)
04 Maximum
Voltage
Output
Frequency
(Base
Frequency
Setting unit:0.1Hz
Setting range:0.2 to 400.0Hz
60.0Hz
05 Intermediate
Output
Frequency
Setting unit:0.1Hz
Setting range:0.1 to 399.9 Hz
1.5Hz
06 Intermediate
Output
Frequency
Voltage
Setting unit:0.1 V
Setting range:0.1 to 255.0V
13.2V
(Note 1)
07 Minimum
Output
Frequency
Setting unit:0.1Hz
Setting range:0.1 to 10Hz
1.5Hz
V/f
Pattern
Setting
08 Minimum
Output
Frequency
Voltage
Setting unit:0.1 V,
Setting range:0.1 to 50V
13.2V
(Note 1)
2.7.3
09 Acceleration
Time 1
Setting unit:0.1s,
Setting range:0.0 to 600.0s
10.0s
First
Accel/Decel
Time
Setting
10 Deceleration
Time 1
Setting unit:0.1s,
Setting range:0.0 to 600.0s
10.0s
11 Acceleration
Time 2
Setting unit:0.1s,
Setting range:0.0 to 600.0s
10.0s
Second
Accel/Decel
Time
Setting
12 Deceleration
Time 2
Setting unit:0.1s,
Setting range:0.0 to 600.0s
10.0s
2.7.4
Note:1. For 440 V class, the value is twice as that of 220 V class.