Page 21
Thermocouple T
ype and T
e
mperatur
e
Range
Input T
e
mperatur
e Sensor T
ype
LED Display
T
emperatur
e Range
Thermocouple TXK type
-328 ~ 1440°F (-200 ~ 800°C)
Thermocouple U type
-328 ~ 932°F (-200 ~ 500°C)
Thermocouple L type
-328 ~ 1562°F (-200 ~ 850°C)
Thermocouple B type
212 ~ 3272°F (100 ~ 1800°C)
Thermocouple S type
32 ~ 3092°F (0 ~ 1700°C)
Thermocouple R type
32 ~ 3092°F (0 ~ 1700°C)
Thermocouple N type
-328 ~ 2340°F (-200 ~ 1300°C)
Thermocouple E type
32 ~ 1112°F (0 ~ 600°C)
Thermocouple T type2
-4 ~ 752°F (-20 ~ 400°C)
Thermocouple T type1
-328 ~ 752°F (-200 ~ 400°C)
Thermocouple J type2
-4 ~ 752°F (-20 ~ 400°C)
Thermocouple J type1
-148 ~ 1562°F (-100 ~ 850°C)
Thermocouple K type2
-4 ~ 932°F (-20 ~ 500°C)
Thermocouple K type1
-328 ~ 2340°F (-200 ~ 1300°C)
R
T
D
T
ype and T
e
mperatur
e Range
Input T
e
mperatur
e Sensor T
ype
LED Display
T
emperatur
e Range
Platinum Resistance (Pt100) type 3
32 ~ 212°F (0 ~ 100°C)
Platinum Resistance (Pt100) type 2
-4 ~ 932°F (-20 ~ 500°C)
Platinum Resistance (Pt100) type 1
-328 ~ 1112°F (-200 ~ 600°C)
Platinum Resistance (JPt100) type 2
32 ~ 212°F (0 ~ 100°C)
Platinum Resistance (JPt100) type 1
-4 ~ 752°F (-20 ~ 400°C)
Page 22
PRECAUTIONS
DANGER!
Caution! Electric Shock!
1.
Do not touch the AC terminals while the power is supplied to the contr
oller
to pr
event an electric shock.
2.
Make sur
e power is disconnected while checking the unit inside.
3.
The symbol indicates that this Contr
oller is pr
otected thr
oughout by
DOUBLE
INSULA
TION or REINFORCED
INSULA
TION (equivalent to Class
II
of IEC
536).
W
A
RNING!
Mount the contr
oller in a location that will not be subject to excessive
temperatur
e, shock, or vibration. All models ar
e designed for mounting in an
enclosed panel.
1.
Always use r
ecommended solder
-less terminals:
Fork terminals with isolation
(M3 scr
ew
, width is 7.0mm (6.0mm for 32B Series), hole diameter 3.2mm).
Scr
ew size: M3 x 6.5 (W
ith 6.8 x 6.8 squar
e washer). Scr
ew size for 32B
Series: M3 x 4.5 (W
ith 6.0 x 6.0 squar
e washer). Recommended tightening
tor
que: 0.4 N.m (4kgf.cm). Applicable wir
e:
Solid/twisted wir
e of 2 mm
2
,
12AWG to 24AWG. Please be sur
e to tighten them pr
operly
.
2.
Do not allow dust or for
eign objects to fall inside the contr
oller to pr
event it
fr
om malfunctioning.
3.
Never modify or disassemble the contr
oller
.
4.
Do not connect anything to the
“No used” terminals.
5.
Make sur
e all wir
es ar
e connected to the corr
ect polarity of terminals.
6.
Do not install and/or use the contr
oller in places subject to: Dust or corr
osive
gases and liquid, high humidity and high radiation, vibration and shock, high
voltage and high fr
equency
.
7.
Power must be of
f when wiring and changing a temperatur
e sensor
.
8.
Be sur
e to use compensating wir
es that match the thermocouple types when
extending or connecting the thermocouple wir
es.
9.
Please use wir
es with r
e
sistance when extending or connecting a platinum
re
sistance sensor (R
TD).
10.
Please keep the wir
e as short as possible when wiring a platinum r
e
sistance
sensor (R
TD)
to the contr
oller and please r
oute power wir
es as far as
possible fr
om load wir
es to pr
event interfer
ence and induce noise.
11.
This contr
oller is an open-type unit and must be placed in an enclosur
e away
fr
om high temperatur
e, humidity
, dripping water
, corr
osive materials, airbor
ne
dust and electric shock or vibration.
12.
Please make sur
e power cables and signals fr
om instruments ar
e all installed
pr
operly befor
e energizing the contr
oller
, otherwise serious damage may
occur
.
13.
Please do not use acid or alkaline liquids for cleaning. Please use a soft, dry
cloth to clean the contr
oller
.
14.
W
ait at least one minute after power is disconnected to allow capacitors to
discharge, and please do not touch any inter
nal cir
cuit within this period.
15.
This instrument is not fur
nished with a power switch or fuse. Ther
efor
e, if a
fuse or power switch is r
e
quir
ed, install the pr
otection close to the
instrument. Recommended fuse rating: Rated voltage 250 V
, Rated curr
ent
1
A. Fuse type: T
ime-lag fuse.
16.
Note: This contr
oller does not pr
ovide over
curr
ent pr
otection. Use of the
pr
oduct r
e
quir
es that suitable over
curr
ent pr
otection device(s) must be
added to ensur
e compliance with all r
elevant electrical standar
ds and codes.
(Rated 250 V
, 15 Amps max). A suitable disconnecting device should be
pr
ovided near the contr
oller in the end-use installation.
Содержание Mini-Pack
Страница 2: ......
Страница 6: ...ACE BOILER INC Page 5 Parts of the Mini Pack ...
Страница 11: ...ACE BOILER INC Page 10 Installation Diagram Single Wall ...
Страница 12: ...ACE BOILER INC Page 11 Installation Diagram Double Wall ...
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 72: ......
Страница 98: ......
Страница 99: ......