Programming Summary
Factory
Parameter
Function
Default
THIS SYSTEM
Pr0
Reading Direction
0
______
Pr1
Segment Offset
1 - On
______
Pr2
High Speed ReadHead
0 - Off
______
Pr3
Zero, Offset Entry
1 - Enable
______
Pr4
Display Resolution
1 - Normal
______
Pr5
mm or cm
0 - mm
______
Pr6
Fractions, mm, in
0 - all
______
Pr7
Scaling
1.0000 (none)
______
Pr8
Auto off
15 - 15 min.
______
Pr9
Auxiliary Keypad
7 - all keys
______
Pr10
Offset Addition
0 - disabled
______
Pr11
Offset Addition 1
1.000 Inch
______
Pr12
Offset Addition 2
1.500 Inch
______
Pr13
Offset Addition 3
2.000 Inch
______
Pr14
Output Mode
0 - off
______
Pr15
Output Polarity
0 – Normally Open ______
Pr16
Lower Limit
0.000
______
Pr17
Upper Limit
5.000 Inch
______
Pr18
Drift Tolerance
.010 Inch
______
Pr19
Auto Monitor ON
0 - disabled
______
Pr20
Auto Monitor OFF
0 - disabled
______
Pr21
Auto Monitor Distance
.500 Inch
______
Pr22
Backlight On
4 - Always
______
Pr23
FUTURE FEATURE
1
______
Pr24
RF Display Address
0 – Off
______
Pr25
RF System ID
0
______
Pr26
Noise Suppression
0 – Minimum
______
Pr27 *
Accuracy Comp. Enable 1 – ON
______
Pr28 *
Compensation Multiple
5 – 5 in.
______
* Pr27 and Pr28 are only operational with a special version of Firmware.
ProScale Display units that support the
Compensation
feature have a “C” at
the end of the firmware revision ID. (The Firmware Version is momentarily
displayed on power-up).
Pressing and holding the
ON/OFF
key and
MODE
key for 10 seconds
with power off
will perform a full segment LCD test AND set all
Programming Parameters to factory defaults.
Note: Defaulting the display to factory defaults will NOT erase the