Accurate Technology ProScale
Page 32 of 48
Pr22 – Backlight ON time
[0, 1, 2, 3 or
4
]
The ON time of the LCD backlighting (24VDC Displays only).
0 = always off.
1 = 3 seconds.
2 = 7 seconds.
3 = 15 seconds.
4 = always on.
NOTE: Backlighting is activated when a key is pressed.
Pr 23 Future Use
[
1
]
DO NOT CHANGE
Pr 24 Display RF Address
[
0
to 63]
This parameter is used to set the address of the Display.
0= (RF off)
Pr 25 RF System ID
[
0
to 31]
This parameter is used to set the ID of the Display system (or
family).
Pr 26 Noise Suppresion
[
0
..7]
This setting helps filter error causing interference caused by stray
electrical noise when the Display is mounted on or around a
machine.
0 = Minimum filtering
7 = Maximum filtering
Pr 27 Accuracy Compensation Enable *
[0,
1
]
This setting enables the ProScale Display measurement
compensation feature.
0 = Compensation Off
1 = Compensation On
Pr 28 Compensation Multiple *
[
5
]
This value is the length of the measurement standards used for
Accuracy Compensation Calibration.
The default is 5 inches. If some other multiple (length) is used,
change this value to match the multiple (length). i.e. 6”.
* Pr27 and Pr28 are operational ONLY on Displays with Firmware versions
ending in “C”