ProScale M150, M250 with LCD Digital Displays
Page 29 of 48
Pr0
–
Reading Direction
[
0
,1]
Change/Reverse the direction (+ vs -) of readings.
Pr1 – Enable/Disable Segment Offset
[0,
1
]
0 = For ALL Incremental Scales
1 = For All ABSOLUTE Scales
Pr2 – High Speed ReadHead
[
0
, 1]
0 = Normal ReadHead
1 = High Speed ReadHead
Use
only
if instructed. A setting of 1 will impact battery life.
Pr3 – Enable/Disable the +, - and ZERO keys
[0,
1
]
0 = Disables operation of Zero, + and – keys (Forced Lock Mode).
1 = Enables operation of Zero, + and – keys.
Pr4 – Display Resolution
[0,
1
, or 2]
Sets the displayed resolution. (No change in fractions mode.)
0 = Reduced resolution
Inch = xxx.xx MM = xx.x
1 = Normal resolution
Inch = xxx.xxx MM = xx.xx
2 = Increased resolution*
Inch = xx.xxxx (no change in mm)
*(Automatic scaling will allow measurements of over 100 inches
when in high resolution. Measurements over 100 inches will
automatically be reduced to 3 decimal places.)
Pr5 – Metric Display Units
[
0
, 1]
Controls whether the measured value is displayed in millimeters or
centimeters when metric mode is selected.
0 = millimeters
1 = centimeters
Pr6 – Disable Fractions/Inches
[
0
, 1, 2]
0 = All measurement modes (mm or cm, inches and fractions).
1 = No Fractions. Only decimal inches and metric units*.
2 = Only Metric. No Imperial (inches or fractions) will be displayed.
*
Pr5 will determine if mm or cm are displayed for metric units.
Pr7 – Scaling Factor
[.0001 .. 99.9999]
Default = 1.0000
(No Scaling.)
The multiplier applied to the measurement. Scaling factors less than
1.0000 will make the displayed measurement less that the actual
measurement. Scaling factors greater than 1.0000 will make the
displayed measurement greater than the actual measurement.