Accurate Technology ProScale
Page 30 of 48
Pr8 – Automatic Power Off
[0 to 60]
Default = 15
Sets the amount of time in ‘minutes without activity’ before the
Display automatically turns off.
0 = Disables Automatic Power Off.
ReadHead motion or ON/OFF key will “wake-up” the Display and
reset the timer.
Pr9 – Auxiliary Keys Enable/Disable
[0..
7
]
0 = ABS/INC, MON and HOLD Disabled
1 = ABS/INC Key Enabled
2 = MON Key Enabled
4 = HOLD Key Enabled
7 = All Keys Enabled
To enable keys, add up combination of key values. A value of 2
enables only the MON key. A value of 7 enables all 3 keys.
Pr10 – Offset Addition Enable
[
0
, 1]
0 = Offset Addition Disabled.
1 = Offset Addition Enabled.
SEE ALSO Pr11, Pr12, Pr13.
Pr11 – Offset Addition 2
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]
Default = 1.000
in.
(25.40mm)
When offset 2 is selected (see Section 4:
O
FFSET
A
DDITION
),
this value is added to the current ABS position.
Only active if Pr10 is set to 1.
Default is set in Inches.
Pr12 – Offset Addition 3
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]
Default= 1.500
in.
(38.10mm)
When offset 3 is selected (see Section 4:
O
FFSET
A
DDITION
),
this value is added to the current ABS position and displayed.
Only active if Pr10 is set to 1.
Default is set in Inches.
Pr13 – Offset Addition 4
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]
Default= 2.000
in.
(50.80mm)
When offset 4 is selected (see Section 4:
O
FFSET
A
DDITION
),
this value is added to the current ABS position and displayed.
Only active if Pr10 is set to 1.
Default is set in Inches.