Product

Order No.

Data interface,

mounting kit

– RS-232 interface with cable

YADAP-RS

– USB interface with cable

YADAP-USB

Data printer

YDP03-0CE

Lock-down capability

LC-1

(for anti-theft locking device)

Calibration weights 

– for VIC-5101 (5 kg; F2)

YCW6548-00

– for VIC-3101 (2 kg; F2)

YCW6248-00

– for VIC-1501 (1 kg; M1)

YCW615-00

– for VIC-10KG (5 kg; M1)

YCW655-00

– for VIC-6KG (5 kg; M2)

YCW656-00

– for VIC-4KG (2 kg; M2)

YCW626-00

– for weight compartment, 

(right side), (100 g; F1)

69V00006

Product

Order No.

In-use cover:

– for models without glass draft shield

69V00001

– for models with glass draft shield

69V00002

Round glas draft shield

69V00003

(25 mm high)

Weighing pan:

– Round

69V00004

– Rectangular

69V00005

Leveling feet

(set of one 

adjustable foot and one fixed foot)

69V00007

Covers: (set of small parts)

69V00008

– Battery compartment
– Interface port
– Weight compartment

Accessories (Options)

C

Marking

The balance/scale complies with the following EC Directives
and European Standards:

Council Directive 89/336/EEC “Electromagnetic
compatibility (EMC)”

Applicable European Standards:
Limitation of emissions:
In accordance with product standard EN 61326-1 Class B 
(residential area)

Defined immunity to interference:
in accordance with product standard EN 61326-1
(minimum test requirements, non-continuous operation)

Important Note:
The operator shall be responsible for any modifications to 
Acculab equipment and must check and, if necessary, correct
these modifications.
On request, Acculab will provide information on the minimum
operating specifications (in accordance with the Standards 
listed above for defined immunity to interference).

73/22/EEC “Electrical equipment designed for
use within certain voltage limits”

Applicable European Standards:

EN 60950
Safety of information technology equipment including electrical
business equipment

EN 61010
Safety requirements for electrical equipment for measurement, 
control and laboratory use 
Part 1: General requirements

If you use electrical equipment in installations 
and under ambient conditions requiring higher safety standards,
you must comply with the provisions as specified in the 
applicable regulations for installation in your country.

Visit www.balances.com for the best prices on Acculab scales

www.balances.com is the original deep discount distributor

Содержание 98648-013-61

Страница 1: ...ULAB VICON Electronic Precision Scales Balances Elektronische Pr zisionswaagen Balances lectroniques d analyse et de pr cision Bilance elettroniche di precisione Balanzas electr nicas de precisi n Vis...

Страница 2: ...autions Safety Information To prevent damage to the equip ment please read these operating instructions carefully before using your balance scale Do not use this equipment in hazardous areas Make sure...

Страница 3: ...top of one another at a time Installation Choose a location that is not subject to the following nega tive influences Heat heater or direct sunlight Drafts from open windows and doors Extreme vibrati...

Страница 4: ...ve the compartment cover Install the battery in the compart ment Make sure the polarity is correct Close the battery compartment slide the cover into position until it snaps into place Do not throw aw...

Страница 5: ...e Keys ON OFF On off key switches the balance scale on and off or switches it to the standby mode Battery operation on turns backlight on off ZERO Zeros the balance press and hold 2 seconds opens the...

Страница 6: ...version factor Display 1 user Grams 1 00000000000 o 2 grams factory setting Grams 1 00000000000 g 4 carat Carats 5 00000000000 o 5 Pound Pounds 0 00220462260 lb 6 ounce Ounces 0 03527396200 oz 7 tryo...

Страница 7: ...uantity 20 on the balance scale 7 Select reference sample quantity in increments of 1 1 2 3 99 or F repeatedly briefly or in increments of 10 10 20 30 100 F 2 sec 8 Confirm selected reference sample q...

Страница 8: ...6 Place the reference weight for 100 on the balance scale 7 If desired change the number of decimal places displayed 100 0 100 00 or 100 factory setting F repeatedly 8 Confirm selected no of decimal p...

Страница 9: ...alance scale ZERO 5 Place oversized sample on balance scale 6 Start application program F Symbol flashes on the display the weight value is locked 7 Unload the balance scale the weight value remains d...

Страница 10: ...ce scale 8 Place the next sample on the balance scale in this example 575 g 9 Store value in memory Totalized stored weight ENTER is displayed symbol flashes Note symbol remains on indicating stored v...

Страница 11: ...display airval ENTER 7 Determine weight of the sample in air place sample on the balance scale 8 Store weight in air value ENTER 9 Remove sample from balance scale 10 Determine weight of sample in liq...

Страница 12: ...libration weight value and ENTER start calibration span adjustment After the zero point is stored the required calibration weight flashes on the display 6 Place the required calibration weight on the...

Страница 13: ...1 3 Stability range 1 3 1 1 4 digit 1 3 2 1 2 digit 1 3 3 1 digit 1 3 4 2 digits 1 3 5 4 digits 1 5 Calib adjust linearization 1 5 1 Calibration adjustment Function of the CAL key 1 5 2 Linearization...

Страница 14: ...aded Unload the balance scale appErr Weight is too light or Increase the weight on the balance scale there is no sample on the balance scale with application in use PrtErr Data interface for Contact t...

Страница 15: ...eable fully ch NiMH avg h 2 5 2 5 4 Model VIC 5101 VIC 3101 VIC 1501 VIC 711 VIC 511 VIC 10KG VIC 6KG VIC 4KG Weighing capacity g 5100 3100 1500 710 510 10100 6100 4100 Readability g 0 1 0 1 0 1 0 1 0...

Страница 16: ...Standards Limitation of emissions In accordance with product standard EN 61326 1 Class B residential area Defined immunity to interference in accordance with product standard EN 61326 1 minimum test r...