B. The Glue / Water System
To keep your machine running properly...
YOU MUST USE THE PROPER GLUE
YOU MUST NOT RUN OUT OF GLUE OR WATER.
YOU MUST FLUSH THE GLUE FROM THE MACHINE AFTER EVERY TIME YOU
USE IT.
YOU MUST FLUSH THE ENTIRE SYSTEM WITH HOT WATER ONCE A
MONTH.
1. Use the proper type of glue.
a. Use a good quality glue that is designed for automatic dowel inserters.
We recommend you use Franklin tightbond doweling glue L.V. or Franklin Assembly
161. Do not use standard white or yellow type wood glue.
b. Glue designed for automatic dowel inserters is a low viscosity glue, with the same proper-
ties as standard glue. The proper glue will flow through the machine smoothly and be ab-
sorbed into the dowel and wood quickly after being inserted. If you have a problem getting
glue or have any questions please call us and we will recommend a source where it can be pur-
chased.
2. Have the Glue Timer set properly.
a. There is a timer located on the bottom shelf in the
valve panel. This timer allows you to adjust the
amount of glue that comes out of the tip per cycle.
You may change the amount of glue by turning the dial.
The normal setting for doweling with glue is: the
first line above 0
The normal setting for doweling with water is: at 0
3.
Set the air pressure in the pressure pot. If you are using glue, it should be set between 30-50
psi. If you are using water, it should be set between 5-15 psi.
4.
We recommend that you check your glue and or water level on a regular basis, depend-
ing on how often and to what extent you use your machine.
a. If you run out of glue while using the machine, air will be put through the system,
and may cause glue to dry in the valves.