6: Alarms
Alarm settings
89
Chapter 6: Alarms
Alarm settings
General alarm settings are defined on the
Alarm > General
page.
Note:
For a list of all supported alarms, see Appendix A.
Notification
There are four mechanisms for alarm reporting: LED, syslog, SNMP, and 802.3AH.
•
Enable LED reporting:
Reports alarms by activating the appropriate EtherNID LED
corresponding to the severity of the alarm.
•
Enable syslog reporting:
Reports alarms by creating syslog entries.
•
Enable SNMP reporting:
Reports alarms via SNMP traps from Accedian’s private MIB.
•
Enable 802.3AH reporting:
Reports alarms via 802.3AH organization specific
OAMPDUs.
Thresholds
•
Threshold on (soaking time in msecs):
Delay after an event is detected before the
alarm notification occurs.
•
Threshold off (soaking time in msecs)
: Delay after an event clears before the alarm
clear notification occurs.